Текст страницы
Troubleshooting
The phenomenon
Reasons
Treatment failure
Contact a repair specialist
an authorized center.
The water temperature is
too high
Damage to the water temperature
control system.
Water flows from the body
of the appliance
1. Destruction of the inner tank
(corrosion).
Contact a repair specialist
an authorized center.
2. The seal at the connection point
of the heating element is broken.
1. Damage to the temperature
control device.
Contact a repair specialist
an authorized service center.
2. The temperature limiter has been
activated or not activated
Indicator do not light, water
does not heat up
Turn on the thermal switch,
following the instructions for
turning it on.
3. Damage to the temperature
limiting device.
Contact a repair specialist
an authorized service center.
1. The water supply is turned off.
Wait until the water supply is
restored.
2. Too low water pressure.
No water flows from the hot
water tap
Turn on the water heater again
when normal water pressure is
restored.
3. Closed cold water tap.
Open the cold water supply tap.
Water leak
The seal at the pipe connection is
broken.
Replace joint seal.
Electrical principal diagram
~230V
Power
indicator
Heating
element
Heating
indicator
fig. 8
15