Инструкция кондиционер настенный сплит-система Samsung AR18BXHQASINUA/AR18BXHQASIXUA

Troubleshooting (стр. 15 из 208)

Бренд: Samsung

Страница 15 документа Кондиционер настенный сплит-система Samsung AR18BXHQASINUA/AR18BXHQASIXUA. Раздел: Кондиционеры (сплит-системы). Бренд: Samsung.

Текст страницы

Issue
Possible Causes

The outdoor unit
makes noises
The unit will make different sounds based on its current operating mode.

Dust is emitted from
either the indoor or
outdoor unit

The unit may accumulate dust during extended periods of non-use, which will be
emitted when the unit is turned on. This can be mitigated by covering the unit during
long periods of inactivity.

The unit may absorb odors from the environment (such as furniture, cooking,
cigarettes, etc.) which will be emitted during operations.

The unit emits a
bad odor

The unit’s filters have become moldy and should be cleaned.

The fan of the outdoor
unit does not operate
During operation, the fan speed is controlled to optimize product operation.

Operation is erratic,
unpredictable, or
unit is unresponsive

Interference from cell phone towers and remote boosters may cause the unit to
malfunction.
In this case, try the following:
• Disconnect the power, then reconnect.
• Press ON/OFF button on remote control to restart operation.

NOTE: If problem persists, contact a local dealer or your nearest customer service center. Provide
them with a detailed description of the unit malfunction as well as your model number.

Troubleshooting

Troubleshooting

When troubles occur, please check the following points before contacting a repair company.

Problem
Possible Causes
Solution

Temperature setting may be higher
than ambient room temperature
Lower the temperature setting

The heat exchanger on the indoor
or outdoor unit is dirty
Clean the affected heat exchanger

The air filter is dirty
Remove the filter and clean it according to
instructions

Poor Cooling
Performance

The air inlet or outlet of either
unit is blocked
Turn the unit off, remove the obstruction
and turn it back on

Doors and windows are open
Make sure that all doors and windows are
closed while operating the unit

Excessive heat is generated
by sunlight
Close windows and curtains during periods
of high heat or bright sunshine

Too many sources of heat in the
room (people, computers,
electronics, etc.)
Reduce amount of heat sources

Low refrigerant due to leak
or long-term use
Check for leaks, re-seal if necessary and
top off refrigerant

SILENCE function is activated
(optional function)
SILENCE function can lower product
performance by reducing operating
frequency. Turn off SILENCE function.

 Page 14 