Step 3: Drill wall hole for connective piping
1. Determine the location of the wall hole based
on the position of the mounting plate. Refer
to Mounting Plate Dimensions.

Type A
Type B

402mm(15.8in)

237mm(9.3in)

148mm(5.8in)

39mm
(1.5in)

39mm
(1.5in)

Indoor unit
outline

47mm
(1.85in)

285mm (11.2in)
47mm
(1.85in)

Left rear wall
hole 65mm (2.5in)
Right rear wall
hole 65mm (2.5in)

107mm(4.2in)
130mm(5.1in)

45mm(1.7in) 103mm(4.1in)

2. Using a 65mm (2.5in) or 90mm(3.54in)
(depending on models )core drill, drill a
hole in the wall. Make sure that the hole
is drilled at a slight downward angle, so
that the outdoor end of the hole is lower
than the indoor end by about 5mm to 7mm
(0.2-0.275in). This will ensure proper water
drainage.
3. Place the protective wall cuff in the hole. This
protects the edges of the hole and will help
seal it when you finish the installation process.

715mm(28in)

Model A

411mm(16.2in)

230mm(9.1in)
246mm(9.7in)

39mm
(1.5in)

CAUTION
When drilling the wall hole, make sure to
avoid wires, plumbing, and other sensitive
components.

39mm
(1.5in)

Indoor unit
outline

47mm
(1.85in)

Wall
Indoor
Outdoor

285mm (11.2in)
47mm
(1.85in)

Left rear wall
hole 65mm (2.5in)
Right rear wall
hole 65mm (2.5in)

45mm(1.7in)
107mm(4.2in)

185mm(7.3in)
139mm(5.5in)

805mm(31.7in)

Model B

458mm(18in)

m
m
7
-
5
(0.2-0.275in)

285mm(11.2in)
243mm(9.57in)

36mm
(1.4in)

Indoor unit
outline

MOUNTING PLATE DIMENSIONS

36mm
(1.4in)
47mm
(1.85in)

302mm (11.88in)

47mm
(1.85in)

Left rear wall
hole 65mm (2.5in)
Right rear wall
hole 65mm (2.5in)

45mm(1.7in) 240mm(9.5in)
143mm(5.6in) 100mm(3.9in)
958.3mm(37.7in)

Model C

559mm(22in)

264mm(10.4in)

344mm(13.5in)

Different models have different mounting plates.
For the different customization requirements, the
shape of the mounting plate may be slightly
different. But the installation dimensions are the
same for the same size of indoor unit.
See Type A and Type B for example:

55mm
(2.16in)

Correct orientation of Mounting Plate

45mm(1.77in)
45mm(1.77in)

47mm
(1.85in)

324.9mm (12.79in)

55mm
(2.16in)
47mm
(1.85in)

219mm(8.6in)

299mm(11.8in)

Left rear wall
hole 65mm (2.5in)
Right rear wall
hole 65mm (2.5in)

1037.6mm(40.85in)

Indoor Unit
Installation

Model D

Φ

NOTE: When the gas side connective pipe is
16mm(5/8in) or more, the wall hole should
be 90mm(3.54in).

 Page 20 