Инструкция D-Link DGS-3130-54TS/B1A

Страница 9 (стр. 9 из 25)

Бренд: D-Link

Страница 9 документа D-Link DGS-3130-54TS/B1A. Раздел: Коммутаторы. Бренд: D-Link.

Текст страницы

for monitoring and configuring the Switch.

To use the RJ-45 console port, the following equipment is needed:


A terminal or a computer with both an RS-232 serial port and terminal emulation
software

A console cable with a male DB9 connector on one end and an RJ-45 connection
on the other

To connect the RJ-45 console port on the Switch to the computer:


Connect the male DB9 connector on the console cable (shipped with the Switch) to
the RS-232 serial port on the computer running terminal emulation software then
insert the RJ-45 connector into the RJ-45 console port on the rear of the Switch.

To configure the terminal emulation software as follows:


Select the appropriate serial port (COM1 or COM2).

Set the data rate to 115200 baud.

Set the data format to 8 data bits, 1 stop bit, and no parity.

Set flow control to none.

Figure 13 — COM Port Configuration

To be able to view the boot procedure, the Switch needs to be rebooted. The simplest way,
at this stage, to reboot the Switch is to unplug and re-insert the power cable from and into
the power receptacle on the back of the Switch. After correctly configuring the terminal
settings and re-inserting the power cable, the boot procedure will appear in the terminal.

9

Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

Aruba 2930F JL262A

9 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

CUDY GS2008PS2

2 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-1210-10MP/F3A

12 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-1210-10MP/F3A

12 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-3130-54TS/B1A

25 стр.