Текст страницы
11. TRANSFORMATION FROM NATURAL GAS TO LPG AND FROM LPG TO
NATURAL GAS
1. Turn off gas and electricity of the hob. If your hob is hot,
wait for cooling down.
2.For injector change, use a screwdriver whose edge is as the Figure 4.
3. As seen in Figure 5, demount burner lid and burner of the hob and ensure
visibility of injector.
Figure 5
Figure 4
Figure 6
5. After that, detach control switches of the hob. Make setting by turning the
screw in the middle of gas cocks with a small screwdriver in the manner shown
in the following picture. To adjust flow rate screw, use a screwdriver having
suitable dimension. For LPG, turn the screw clockwise. For natural gas, turn
the screw one time counter clockwise. At low position, length of normal flame
should be 6-7 mm. For the last control, check out whether flame is open or
closed. Setting of your appliance may differ according to the type of gas cock
used.
Figure 8
Figure 7
12. GAS BREAKING SAFETY APPLIANCE (FFD)
FFD
Figure 9
Against putting out to be taken place as a result of liquid
overflow at upper burners, safety appliance steps in and
cut gas immediately.
41