1 Device installation
1.1 Safety precautions
Signal lightning arrester
Ethernet cable
Step 3 Mount the switch at a proper height on the rack and fix the L-shaped brackets
to the rack with screws (self-prepared). Ensure that the switch is stable on the
rack.
Other network
devices
Grounding cable
Grounding
terminal
Before performing an operation, read the operation instructions and precautions to be
taken, and follow them to prevent accidents. The warning and danger items in other
documents do not cover all the safety precautions that must be followed. They are
only supplementary information, the installation and maintenance personnel need to
understand the basic safety precautions to be taken.
Step 2 Place the switch horizontally onto the wall with its RJ45 ports facing
upward, and then mark the positions of the screw holes with the marker.
Step 3 Drill holes in the marked positions, and then hammer the expansion
bolts (self-prepared, M5*40 mm) into the holes.
Step 4 Use a screwdriver to secure the screws (self-prepared, PA5*25 mm,
head diameter: 10 mm) passing through the L-brackets into the
expansion bolts. Ensure that the switch is installed firmly with its RJ45
ports facing upward.
Quick Installation Guide
Note:
L3 Managed Switch With 4-Port 10G SFP+
G5328X
There is a void sticker covering one of the screws on the housing of the switch. Do NOT remove
the sticker without permission of the local agent. Otherwise you shall be responsible for any
damage.
1.2 Preparation for installation
Wall mounting
Note:
- This switch can only be installed on non-flammable walls, such as a concrete wall.
- Do NOT install the switch with its ventilation openings facing downward; otherwise, there will
be potential safety hazards.
- The switch is only suitable for mounting at heights ≤ 2 m.
- Rack mounting: ESD bracelet or gloves, screwdriver, 4 screws (suitable for securing
the switch to the rack)
- Wall mounting: ESD bracelet or gloves, marker, hammer drill, rubber hammer,
screwdriver, 4 expansion bolts (M5*40 mm), 4 screws (PA5*25 mm, head diameter:
10 mm)
- Desktop mounting: ESD bracelet or gloves
Step 1 Fix the 2 L-shaped brackets (rotated by 90 degrees) to both sides of the
switch with the included screws.
Desktop mounting
1.3 Installation
Package contents
Rack mounting (mount to a standard 19-inch rack)
Paste the four footpads to the corresponding four recesses on the bottom of the
switch. Then turn the switch upside down, and place it horizontally on a big
enough, clean, stable and flat desktop.
Footpad
Switch x 1 Power cord x 1 Console cable x 1
L-shaped bracket x 2 Footpad x 4 Screw (KM3*8 mm) x 8
Quick installation guide x 1
Step 1 Ensure that the rack is stable and level, and is properly grounded.
Step 2 Fix the 2 L-shaped brackets to both sides of the switch with the included
screws.
1. Do not use this apparatus near water.
2. Clean only with dry cloth.
3. Do not block any ventilation openings, such as newspapers, table-cloth, curtains,
etc.
4. Do not install near any heat sources such as radiators, heat registers, stoves or
other apparatus that produce heat.
5. Do not damage the ground conductor or operate the device in the absence of well
installed ground conductor. Conduct the appropriate electrical inspection.
6. Protect the power cord from being walk on or pinched particularly at the plugs,
convenience receptacles and at the point where they exit from the apparatus.
7. Only use attachments/accessories specified by the manufacturer.
8. Unplug this apparatus during lightning storms or when unused for long periods of
time.
9. Mains plug is used as the disconnect device, the disconnect device shall remain
readily operable.
10. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
11. Warning: To reduce the risk of fire or electric shock, do not expose this apparatus
to rain or moisture. The apparatus shall not be exposed to dripping or splashing.
12. Warning: To reduce the risk of electric shock, do not remove cover as there no
user-serviceable parts inside. Refer servicing to qualified personnel.
13. If an outdoor cable is required, check whether the signal lightning arrester and AC
surge arrester are connected to the switch.
This guide instructs how to install, connect and log in to the device. For details, please visit
www.ip-com.com.cn to download the user guide of the device.
2 Device connection
1.4 Grounding
Grounding is important for lightning protection, anti-interference, and personal safety.
Refer to the following network topology to connect the switch to other network devices.
After connection, please check whether the switch is connected properly according
to the following table.
Internet
Router
Step 1 Connect one end of the grounding cable to the grounding terminal of the
switch.
Step 2 Connect the other end of the grounding cable to another grounded device or
to the binding post on the grounding bar.
LED indicator
Description
This switch
LAN port
WAN port
SYS
Blinking: The system works properly.
Solid on: The system is not working properly.
Off: The system is starting up or not working properly.
This switch
PoE switch
Power
Solid on: The switch is powered on properly.
Off: The switch is not powered on, or not powered on properly.
Other devices
NVR
Link/Act
(1 - 24)
Grounding terminal
Solid on: The port is connected to a device, but no data is being
transmitted over the port.
Blinking: Data is being transmitted over the port.
Off: The port is not connected or is not connected properly.
Green light indicates that the negotiation rate of the port is 1000
Mbps, while orange light indicates a rate of 10 Mbps or 100 Mbps.
AP
IP camera
Grounding cable
PoE switch
Grounding bar
Link/Act
(25 - 28)
OR
Solid on: The port is connected to a device, but no data is being
transmitted over the port.
Blinking: Data is being transmitted over the port.
Off: The port is not connected or is not connected properly.
Technical Support
Tips
Grounding terminal
AP
IP camera
The switch supports auto MDI/MDIX, so both a straight cable or a crossover cable can be used
to connect the switch to Ethernet devices.
Grounding cable
PoE switch
Address: Room 101, Unit A, First Floor, Tower E3, No.1001, Zhongshanyuan Road,
Nanshan District, Shenzhen, China. 518052
Tel: (86755) 2765 3089
Email: info@ip-com.com.cn
Website: www.ip-com.com.cn
Grounding bar
FTP Server
Copyright
Connect the grounding cable of the switch to the grounding system in the equipment room.
Do NOT connect it to a fire hose or lightning rod.
Note:
AP
IP camera
©2022 IP-COM Networks Co., Ltd. All rights reserved.
This documentation (including pictures, images, and product specifications, etc.) is for reference only.
To improve internal design, operational function, and/or reliability, IP-COM reserves the right to make
changes to the products described in this document without obligation to notify any person or
organization of such revisions or changes.
V2.0 Keep for future reference
3 Login
1. I cannot log in to the web UI of the switch. What should I do?
FAQ
Step 1 Use an Ethernet cable to connect the computer to one of the ports 1 -
24 of the switch.
Switch
Step 3 Start a web browser (such as Chrome) on the computer, and enter the
default IP address of the switch (default: 10.16.16.168) in the address
bar, and press Enter on the keyboard.
10.16.16.168
Ethernet cable
Computer
Step 4 Enter the login user name and password (both are admin by default)
on the login page of the switch, and click Login.
User Name
Step 2 Set the IP address of Ethernet (or Local Area Connection) of the
computer to the same network segment of the switch’s IP address.
The default IP address of the switch is 10.16.16.168. You can set the
IP address of the computer to 10.16.16.X (X ranges from 2 to 254
excluding 168, and is not occupied) and the subnet mask to
255.255.255.0.
Password
Try the following solutions:
- Check whether the switch is powered on properly: The Power LED indicator is
solid on.
- Check whether the computer is connected to the switch properly with an
Ethernet cable.
- Check whether the IP address of Ethernet (or Local Area Connection) of the
computer is set to 10.16.16.X (X ranges from 2 to 254 excluding 168, and is
not occupied).
- Clear the cache of the web browser or try another web browser.
- Disable the firewall of the computer, or try another computer.
- Check whether only one device with the IP address 10.16.16.168 exists in the
local network.
- If the problem persists, reset the switch and try again.
Reset method: When the SYS LED indicator is blinking, press and hold the
Reset button for about 10 seconds, and then release it when all indicators are
solid on. When the SYS LED indicator blinks again, the switch is restored to
factory settings.
2. I forget the login user name and password when logging in to
the web UI. What should I do?
Step 3 Press Enter twice and enter the user name and password of
the switch (both are admin by default) on the page to enter the
command-line interface of the switch.
English
Forget password
COM1 - PuTTY
Login
Try entering the default login user name and password (both are admin). If you
still fail to log in to the web UI, reset the switch, then use the default user name
and password to log in.
Username: admin
Password:
G5328X
20
16
16
10
3. How do I connect the switch through the Console port?
Tips
255
255
255
0
If you fail to access the above page, please refer to question 1 in FAQ.
After successfully logging in to the web UI of the switch, you can configure the
switch now.
Please operate as follows:
Step 1 Connect the computer and the Console port of the switch with the
included console cable.
Step 2 Run a serial interface connection software (such as PuTTY) on the
computer. Enter 115200 in the Speed box and select Serial as the
Connection type. Then click Open.
Specifications
English
арактеристики
Русский
Спецификации
Български
Spezifikationen
Deutsch
Specifiche
Italiano
Model
G5328X
Модель
G5328X
Модел
G5328X
Modell
G5328X
Modello
G5328X
24
24
24
24
24
10/100/1000 Mbps
RJ45 port
Порт RJ45 10/100/
1000 Мбит/с
10/100/1000 Mbps
RJ45 порт
10/100/1000 Mbit/s
RJ45-Port
Porta RJ45 10/100/
1000 Mbps
Порт
Port
Porte
Port
Порт
4 porte SFP+ indipendenti
4 независимы SFP+ порта
Порт SFP+ 10000 Мбит/с
4 независими SFP+ порта
Porta SFP+ 10000 Mbps
4 independent SFP+ ports
4 unabhängige SFP+-Ports
10000 Mbit/s SFP+-Port
10000 Mbps SFP+ port
10000 Mbps SFP+ порт
1; Velocità: 115200
Porta console
1; Baud rate: 115200
1; Скорость передачи в бода : 115200
1; Скорост на боуд: 115200
1; Baudrate: 115200
Консольный порт
Console port
Конзолен порт
Konsolen-Anschluss
Store-and-forward
Modalità switching
Со ранение и дальнейшая передача
Режим переключения
Modus wechseln
Store-and-forward
Speichern und weiterleiten
Съ раняване и препращане
Switching mode
Режим на
превключване
Auto invecchiamento, auto apprendimento
Автоматические старение, автоматическое обучение
выполнение
Performance
Prestazioni
Leistung
Automatisches Altern, automatisches Lernen
Auto aging, auto learning
Автоматично навършени, автоматично обучение
Apprendimento degli
indirizzi MAC
Изучение MAC-
адресов
MAC address table
learning
MAC-Adressentabelle
lernen
Таблица с MAC
адреси, обучение
Тенически
показатели
16 K
16 K
16 K
16 K
16 K
Таблица MAC-адресов
Таблица с MAC адреси
MAC-Adressentabelle
MAC address table
Tabella degli indirizzi
MAC
440 мм x 179,6 мм x 44 мм
440 mm x 179,6 mm x 44 mm
440 mm x 179,6 mm x 44 mm
Dimensions (L x W x H)
440 mm x 179.6 mm x 44 mm
Размеры (Д Ш В)
Размери (Д Ш В)
Dimensioni (L x P x A)
Abmessungen (L x B x H)
440 mm x 179,6 mm x 44 mm
Водное напряжение
Водящо напрежение
Input voltage
Tensione di ingresso
Nennspannung
100–240 В перем. тока, 50/60 Гц, 0,7A
100 - 240V AC, 50/60Hz, 0.7A
100 - 240 V CA, 50/60 Hz, 0,7A
100 – 240 V AC, 50/60 Hz, 0,7 A
100 - 240 V AC, 50/60 Hz, 0,7A
Common mode: 6 kV
Обычный режим: 6 kV
Normaler Modus: 6 kV
Modalità comune: 6 kV
Общ режим: 6 kV
Порт RJ45
RJ45 порт
RJ45 port
RJ45-Port
Porta RJ45
Lightning
protection
Common mode: 6 kV ; Differential mode: 4 kV
Обычный режим: 6 kV;Дифференциальный режим: 4 kV
Modalità comune: 6 kV; Modalità differenziale: 4 kV
Общ режим: 6 kV ; Диференциален режим: 4 kV
Normaler Modus: 6 kV; Differentialmodus: 4 kV
Источник питания
Молниезащита
Заранване
Мълниезащита
Power supply
Stromversorgung
Blitzschutz
Alimentazione
Protezione
contro i
fulmini
Рабочая среда
Работна среда
Operating environment
Betriebsumgebung
Температура: 0°C - 45°C
Влажность: (10–90%) без конденсации
Температура: 0°C - 45°C
Влажност: (10% – 90%) RH, некондензиращи
Ambiente operativo
Temperature: 0°C - 45°C
Humidity: (10% - 90%) RH, non-condensing
Temperatur: 0°C - 45°C
Luftfeuchtigkeit: (10 % - 90 %) RH, nicht kondensierend
Temperatura: 0°C - 45 °C
Umidità: 10% - 90% UR, senza condensa
Условия ранения
Среда за съранение
Lagerumgebung
Storage environment
Температура: -40°C - 70°C
Влажность: (5–90%) без конденсации
Ambiente di immagazzinaggio
Температура: -40°C - 70°C
Влажност: (5% – 90%) RH, некондензиращи
Temperatur: -40°C - 70°C
Luftfeuchtigkeit: (5% - 90 %) RH, nicht kondensierend
Temperature: -40°C - 70°C
Humidity: (5% - 90%) RH, non-condensing
Temperatura: -40°C - 70°C
Umidità: (5% - 90%) UR, senza condensa
Скорость передачи информации
Data transmission rate
Datenübertragungsrate
Скорост на предаване на данни
Velocità di trasmissione dati
Ethernet: 10 Mbit/s (Halbduplex)/20 Mbit/s (Vollduplex)
Fast Ethernet: 100 Mbit/s (Halbduplex)/
200 Mbit/s (Vollduplex)
Gigabit Ethernet: 2000 Mbit/s (Vollduplex)
10 Gigabit Ethernet: 20000 Mbit/s (Vollduplex)
Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex)/
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)
Ethernet: 10 Mbps (half duplex) / 20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex) /
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)
Ethernet: 10 Mbps (полудуплексный)/
20 Mbps (полнодуплексный)
Fast Ethernet: 100 Mbps (полудуплексный)/
200 Mbps (полнодуплексный)
Гигабитный Ethernet: 2000 Mbps (полнодуплексный)
10-Гигабитный Ethernet: 20000 Mbps (полнодуплексный)
Ethernet: 10 Mbps (полудуплекс)/
20 Mbps (пълен дуплекс)
Бърз Ethernet: 100 Mbps (полудуплекс)/
200 Mbps (пълен дуплекс)
Гигабитен Ethernet: 2000 Mbps (пълен дуплекс)
10-гигабитен Ethernet: 20000 Mbps (пълен дуплекс)
Transmission media
Übertragungsmedien
Mezzi di trasmissione
Средства передачи
Среда на предаване
Ethernet: CAT3 UTP/STP-Kabel oder höher
Fast Ethernet: CAT5 UTP/STP-Kabel oder höher
Gigabit Ethernet:CAT5e oder CAT6 UTP/STP Kabel
1000Base-SX: MMF
1000Base-LX: MMF oder SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: CAT3 UTP/STP or better
Fast Ethernet: CAT5 UTP/STP or better
Gigabit Ethernet: CAT5e or CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF or SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: Cavo UTP/STP CAT3 o superiore
Fast Ethernet: Cavo UTP/STP CAT5 o superiore
Gigabit Ethernet: Cavo UTP/STP CAT5E o CAT6
1000Base-SX: MMF
1000Base-LX: MMF o SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: Кабель CAT3 UTP/STP или выше
Fast Ethernet: Кабель CAT5 UTP/STP или выше
Gigabit Ethernet: Кабель CAT5E или CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF или SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: CAT3 UTP/STP или по-добре
Бърз Ethernet: CAT5 UTP/STP или по-добре
Гигабитен Ethernet: CAT5e или CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF или SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Standards
Standard di rete
Стандарты
Standards
Стандарти
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
Especificações
Português
Especificaciones
Español
Spécifications
Français
Dane techniczne
Polski
Specificaţii
Română
Modelo
G5328X
Modelo
G5328X
Modèle
G5328X
Model
G5328X
Model
G5328X
24
24
24
24
24
Porta RJ45 10/100/
1000 Mbps
Puerto RJ45 de 10/
100/1000 Mbps
Port RJ45 10/100/
1000 Mbps
Port RJ45 10/100/
1000 Mb/s
Port RJ45 10/100/1
000 Mbps
Porta
Port
Port
Port
Puerto
4 ports SFP+ indépendants
Port SFP+ 10000 Mbps
4 portas SFP+ independentes
4 niezależne porty SFP+
4 porturi SFP+ independente
4 puertos SFP+ independientes
Porta SFP+ 10000 Mbps
Port SFP+ 10000 Mb/s
Port SFP+ 10000 Mbps
Puerto SFP+ de 10000
Mbps
1; Débit en Baud: 115200
Port de la console
1; Taxa de Baud: 115200
Porta da consola
1; Prędkość transmisji: 115200
1; Rată Baud: 115200
Port konsoli
Port consolă
1; Velocidad en baudios: 115200
Puerto de consola
Stockage et transmission
Guardar e reencaminhar
Mode de commutation
Modo de comutação
Zapis-i-wprzód
Tryb przełączania
Store-and-forward
Switching mode
Almacenar y retransmitir
Modo de conmutación
Envelhecimento automático, aprendizagem automática
Auto vieillissement, auto apprentissage
Automatyczna pamięć adresów i chwili rejestracji
Nauka adresów MAC
Desempenho
Wydajność
Performanţă
Rendimiento
Performance
Aprendizagem de
endereços MAC
Apprentissage des
adresses MAC
Auto aging, auto learning
Vencimiento automático, aprendizaje automático
MAC address table
learning
Aprendizaje de
direcciones MAC
16 K
Tabela adresów MAC
16 K
16 K
16 K
16 K
MAC address table
Tabla de direcciones MAC
Tabela de endereços
MAC
Tableau des adresses
MAC
440 mm x 179,6 mm x 44 mm
Wymiary (dł. x szer. x wys.)
Dimensões (C x L x A)
440 x 179,6 x 44 mm
440 mm x 179,6 mm x 44 mm
440 mm x 179,6 mm x 44 mm
440 mm x 179,6 mm x 44 mm
Dimensiuni (L x l x Î)
Dimensiones (L x An x Al)
Dimensions (L x W x H)
100 - 240V AC, 50/60Hz, 0,7A
Napięcie wejściowe
100 - 240 V c.a., 50/60 Hz, 0,7 A
100-240V AC, 50/60Hz, 0,7 A
100-240V AC, 50/60Hz, 0,7A
100 - 240 V CA, 50/60 Hz, 0,7 A
Tensiune de intrare
Voltaje de entrada
Tension d'entrée
Tensão de entrada
Tryb wspólny: 6 kV
Port RJ45
Mod obişnuit: 6 KV
Modo comum: 6 kV
Mode commun : 6 kV
Modo común: 6 kV
Porta RJ45
Port RJ45
Puerto RJ45
Port RJ45
Proteção
contra raios
Protección
contra rayos
Tryb wspólny: 6 kV; Tryb różnicowy: 4 kV
Zasilanie
Mod obişnuit: 6 KV; Mod diferenţial: 4 KV
Modo comum: 6 kV; Modo diferencial: 4 kV
Mode commun : 6 kV; Mode différentiel : 4 kV
Modo común: 6 kV; Modo diferencial: 4 kV
Fonte de energia
Sursa de alimentare
Fuente de alimentación
Alimentation électrique
Ochrona
przed
piorunami
Protection
contre la
foudre
Protecţie
împotriva
descărcărilor
electrice
Entorno de funcionamiento
Środowisko pracy
Environnement opérationnel
Ambiente operacional
Mediu de funcţionare
Température : 0°C - 45°C
Humidité :(10 % - 90 %) HR, non-condensant
Temperatura: 0-45 °C
Humedad: 10 %-90 % HR, sin condensación
Temperatura: 0°C - 45°C
Umiditate: (10% - 90%) umiditate relativă, fără condens
Temperatura: 0°C - 45°C
Humidade: (10% - 90%) de HR, sem condensação
Temperatura: 0°C - 45°C
Wilgotność: (10–90%) wilgotności względnej,
bez kondensacji
Entorno de almacenamiento
Environnement de stockage
Ambiente de armazenamento
Température : -40°C - 70°C
Humidité : (5 % - 90 %) HR, non-condensant
Temperatura: -40-70 °C
Humedad: 5 %-90 % HR, sin condensación
Mediu de depozitare
Temperatura: -40°C - 70°C
Umiditate: (5% - 90%) umiditate relativă, fără condens
Temperatura: -40°C - 70°C
Humidade: (5% - 90%) de HR, sem condensação
Środowisko przechowywania
Temperatura: -40°C - 70°C
Wilgotność: (5–90%) wilgotności względnej, bez kondensacji
Taux de transmission des données
Velocidad de transmisión de datos
Taxa de transmissão de dados
Viteză de transmisie a datelor
Szybkość transmisji danych
Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Ethernet rápida: 100 Mbps (half duplex)/
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)
Ethernet: 10 Mbps (dúplex medio)/
20 Mbps (dúplex completo)
Fast Ethernet:100 Mbps (dúplex medio)/
200 Mbps (dúplex completo)
Gigabit Ethernet: 2000 Mbps (dúplex completo)
10 Gigabit Ethernet: 20000 Mbps (dúplex completo)
Ethernet : 10 Mbit/s (semi duplex)/
20 Mbit/s (duplex intégral)
Fast Ethernet : 100 Mbit/s (semi duplex)/
200 Mbit/s (duplex intégral)
Gigabit Ethernet : 2000 Mbit/s (duplex intégral)
10 Gigabit Ethernet : 20000 Mbit/s (duplex intégral)
Ethernet: 10 Mbps (semi duplex)/
20 Mbps (duplex complet)
Fast Ethernet: 100 Mbps (semi duplex)/
200 Mbps (duplex complet)
Ethernet Gigabit: 2000 Mbps (duplex complet)
10 Ethernet Gigabit: 20000 Mbps (duplex complet)
Sieć Ethernet: 10 Mb/s (półdupleks) /
20 Mb/s (pełny dupleks)
Szybka sieć Ethernet: 100 Mb/s (półdupleks) /
200 Mb/s (pełny dupleks)
Gigabitowa sieć Ethernet: 2000 Mb/s (pełny dupleks)
10 Gigabit Ethernet: 20000 Mb/s (pełny dupleks)
Support de transmission
Medios de transmisión
Meios de transmissão
Mediu de transmitere
Środki transmisji
Ethernet: Cabo CAT3 UTP/STP ou superior
Ethernet rápida: Cabo CAT5 UTP/STP ou superior
Gigabit Ethernet: Cabo CAT5E ou CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF ou SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: Cable CAT3 UTP/STP o superior
Fast Ethernet: Cable CAT5 UTP/STP o superior
Gigabit Ethernet: CAT5e o UTP/STP CAT6
1000Base-SX: MMF
1000Base-LX: MMF o SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet : CAT3 UTP/STP ou supérieur
Fast Ethernet : CAT5 UTP/STP ou supérieur
Gigabit Ethernet : CAT5e ou CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF ou SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Sieć Ethernet: Kabel CAT3 UTP/STP lub lepszy
Szybka sieć Ethernet: Kabel CAT5 UTP/STP lub lepszy
Gigabitowa sieć Ethernet: Kabel CAT5e lub CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF lub SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: Cablu CAT3 UTP/STP sau o versiune mai nouă
Fast Ethernet: Cablu CAT5 UTP/STP sau o versiune
mai nouă
Ethernet Gigabit: CAT5e sau CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF sau SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Normas
Estándares
Normes
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
Standardy
Standarde
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
Specifikáció
Magyar
Özellikler
Türkçe
Safety and statement
RECYCLING
Modell
G5328X
Model
G5328X
G5328X
24
24
CE Mark Warning
10/100/1000 Mb/s
RJ45 port
10/100/1000 Mbps
RJ45 portu
portok
Port
4 bağımsız SFP+ portu
10000 Mbps SFP+ portu
4 szabad SFP+ port
SFP+
10000 Mb/s SFP+ port
This product bears the selective sorting symbol for Waste electrical and electronic
equipment (WEEE). This means that this product must be handled pursuant to
European directive 2012/19/EU in order to be recycled or dismantled to minimize its
impact on the environment.
1; Baud hızı: 115200
1; átviteli sebesség 115200
Konsol portu
konzol csatlakozó felület
This is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
The mains plug is used as disconnect device, the disconnect device shall remain
readily operable.
Sakla ve gönder
Anahtarlama modu
Tárol és továbbít
User has the choice to give his product to a competent recycling organization or to
the retailer when he buys a new electrical or electronic equipment.
Kapcsolási mód
Otomatik yaşlanma, otomatik öğrenme
MAC adres öğrenme
Performans
Működés
Automatikus elhasználódás, öntanulás
MAC címtáblázat
tanulás
16 K
MAC adres tablosu
16 K
MAC cím táblázat
NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation
interference, it is recommended to use a shielded RJ45 cable.
440 mm x 179,6 mm x 44 mm
Boyutlar (B x E x Y)
440 mm x 179,6 mm x 44 mm
Méretek (H x Sz x M)
100 - 240V AC, 50/60 Hz, 0,7A
Giriş Gerilimi
100-240 V váltóáram, 50/60Hz 0,7 A
Bemeneti feszültség
Ortak mod: 6 kV
RJ45 portu
Közös üzemmód: 6 kV
RJ45 port
Yıldırım
koruması
Villámcsapás
védelem
Ortak mod: 6 kV; Diferansiyel mod: 4 kV
Güç kaynağı
Közös üzemmód: 6 kV; Differenciál üzemmód: 4 kV
Tápellátás
Çalışma ortamı
Működési környezet
Sıcaklık: 0°C - 45°C
Nem: (%10 - %90) RH, yoğuşmasız
Hőfok: 0°C - 45°C
Páratartalom: 10 - 90% RH, nem kicsapódó
Depolama ortamı
Tárolási környezet
Sıcaklık: -40°C - 70°C
Nem: (%5 - %90) RH, yoğuşmasız
Hőfok: -40°C - 70°C
Páratartalom: 5 - 90% RH, nem kicsapódó
Adatátviteli sebesség
Veri iletim hızı
Ethernet: 10 Mb/s (fél duplex)/20 Mb/s (teljes duplex)
Fast Ethernet: 100 Mb/s (fél duplex)/
200 Mb/s (teljes duplex)
Gigabit Ethernet: 2000 Mb/s (teljes duplex)
10 Gigabit Ethernet: 20000 Mb/s (teljes duplex)
Ethernet: 10 Mbps (yarı çift yönlü) /
20 Mbps (tam çift yönlü)
Fast Ethernet: 100 Mbps (yarı çift yönlü) /
200 Mbps (tam çift yönlü)
Gigabit Ethernet: 2000 Mbps (tam çift yönlü)
10 Gigabit Ethernet: 20000 Mbps (tam çift yönlü)
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Átviteli közeg
İletim Ortamları
Ethernet: CAT3 UTP/STP vagy gyorsabb kábel
Fast Ethernet: CAT5 UTP/STP vagy gyorsabb kábel
Gigabit Ethernet: CAT5e vagy CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF vagy SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Ethernet: CAT3 UTP/STP veya daha iyisi
Fast Ethernet: CAT5 UTP/STP veya daha iyisi
Gigabit Ethernet: CAT5e veya CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF veya SMF
10GBase-SR: MMF
10Gbase-LR: SMF
Caution!
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Szabványok
Standartlar
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s
NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation
interference, it is recommended to use a shielded RJ45 cable.