Инструкция коммутатор IP-COM G5328X

1 Device installation (стр. 1 из 1)

Бренд: IP-COM

Страница 1 документа Коммутатор IP-COM G5328X. Раздел: Коммутаторы. Бренд: IP-COM.

Текст страницы

1 Device installation

1.1 Safety precautions

Signal lightning arrester

Ethernet cable

Step 3 Mount the switch at a proper height on the rack and fix the L-shaped brackets
to the rack with screws (self-prepared). Ensure that the switch is stable on the
rack.

Other network
devices

Grounding cable

Grounding
terminal

Before performing an operation, read the operation instructions and precautions to be
taken, and follow them to prevent accidents. The warning and danger items in other
documents do not cover all the safety precautions that must be followed. They are
only supplementary information, the installation and maintenance personnel need to
understand the basic safety precautions to be taken.

Step 2 Place the switch horizontally onto the wall with its RJ45 ports facing
upward, and then mark the positions of the screw holes with the marker.
Step 3 Drill holes in the marked positions, and then hammer the expansion
bolts (self-prepared, M5*40 mm) into the holes.
Step 4 Use a screwdriver to secure the screws (self-prepared, PA5*25 mm,
head diameter: 10 mm) passing through the L-brackets into the
expansion bolts. Ensure that the switch is installed firmly with its RJ45
ports facing upward.

Quick Installation Guide

Note:

L3 Managed Switch With 4-Port 10G SFP+
G5328X

There is a void sticker covering one of the screws on the housing of the switch. Do NOT remove
the sticker without permission of the local agent. Otherwise you shall be responsible for any
damage.

1.2 Preparation for installation

Wall mounting

Note:

- This switch can only be installed on non-flammable walls, such as a concrete wall.
- Do NOT install the switch with its ventilation openings facing downward; otherwise, there will
be potential safety hazards.
- The switch is only suitable for mounting at heights ≤ 2 m.

- Rack mounting: ESD bracelet or gloves, screwdriver, 4 screws (suitable for securing
the switch to the rack)
- Wall mounting: ESD bracelet or gloves, marker, hammer drill, rubber hammer,
screwdriver, 4 expansion bolts (M5*40 mm), 4 screws (PA5*25 mm, head diameter:
10 mm)
- Desktop mounting: ESD bracelet or gloves

Step 1 Fix the 2 L-shaped brackets (rotated by 90 degrees) to both sides of the
switch with the included screws.

Desktop mounting

1.3 Installation

Package contents

Rack mounting (mount to a standard 19-inch rack)

Paste the four footpads to the corresponding four recesses on the bottom of the
switch. Then turn the switch upside down, and place it horizontally on a big
enough, clean, stable and flat desktop.

Footpad

Switch x 1 Power cord x 1 Console cable x 1
L-shaped bracket x 2 Footpad x 4 Screw (KM3*8 mm) x 8
Quick installation guide x 1

Step 1 Ensure that the rack is stable and level, and is properly grounded.
Step 2 Fix the 2 L-shaped brackets to both sides of the switch with the included
screws.

1. Do not use this apparatus near water.
2. Clean only with dry cloth.
3. Do not block any ventilation openings, such as newspapers, table-cloth, curtains,
etc.
4. Do not install near any heat sources such as radiators, heat registers, stoves or
other apparatus that produce heat.
5. Do not damage the ground conductor or operate the device in the absence of well
installed ground conductor. Conduct the appropriate electrical inspection.
6. Protect the power cord from being walk on or pinched particularly at the plugs,
convenience receptacles and at the point where they exit from the apparatus.
7. Only use attachments/accessories specified by the manufacturer.
8. Unplug this apparatus during lightning storms or when unused for long periods of
time.
9. Mains plug is used as the disconnect device, the disconnect device shall remain
readily operable.
10. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
11. Warning: To reduce the risk of fire or electric shock, do not expose this apparatus
to rain or moisture. The apparatus shall not be exposed to dripping or splashing.
12. Warning: To reduce the risk of electric shock, do not remove cover as there no
user-serviceable parts inside. Refer servicing to qualified personnel.
13. If an outdoor cable is required, check whether the signal lightning arrester and AC
surge arrester are connected to the switch.

This guide instructs how to install, connect and log in to the device. For details, please visit
www.ip-com.com.cn to download the user guide of the device.

2 Device connection

1.4 Grounding
Grounding is important for lightning protection, anti-interference, and personal safety.

Refer to the following network topology to connect the switch to other network devices.
After connection, please check whether the switch is connected properly according
to the following table.

Internet
Router

Step 1 Connect one end of the grounding cable to the grounding terminal of the
switch.
Step 2 Connect the other end of the grounding cable to another grounded device or
to the binding post on the grounding bar.

LED indicator

Description

This switch

LAN port

WAN port

SYS

Blinking: The system works properly.
Solid on: The system is not working properly.
Off: The system is starting up or not working properly.

This switch
PoE switch

Power
Solid on: The switch is powered on properly.
Off: The switch is not powered on, or not powered on properly.

Other devices

NVR

Link/Act
(1 - 24)

Grounding terminal

Solid on: The port is connected to a device, but no data is being
transmitted over the port.
Blinking: Data is being transmitted over the port.
Off: The port is not connected or is not connected properly.
Green light indicates that the negotiation rate of the port is 1000
Mbps, while orange light indicates a rate of 10 Mbps or 100 Mbps.

AP
IP camera

Grounding cable

PoE switch

Grounding bar

Link/Act
(25 - 28)

OR

Solid on: The port is connected to a device, but no data is being
transmitted over the port.
Blinking: Data is being transmitted over the port.
Off: The port is not connected or is not connected properly.

Technical Support

Tips

Grounding terminal

AP
IP camera

The switch supports auto MDI/MDIX, so both a straight cable or a crossover cable can be used
to connect the switch to Ethernet devices.

Grounding cable

PoE switch

Address: Room 101, Unit A, First Floor, Tower E3, No.1001, Zhongshanyuan Road,
Nanshan District, Shenzhen, China. 518052
Tel: (86755) 2765 3089
Email: info@ip-com.com.cn
Website: www.ip-com.com.cn

Grounding bar

FTP Server

Copyright

Connect the grounding cable of the switch to the grounding system in the equipment room.
Do NOT connect it to a fire hose or lightning rod.
Note:

AP
IP camera

©2022 IP-COM Networks Co., Ltd. All rights reserved.
This documentation (including pictures, images, and product specifications, etc.) is for reference only.
To improve internal design, operational function, and/or reliability, IP-COM reserves the right to make
changes to the products described in this document without obligation to notify any person or
organization of such revisions or changes.

V2.0 Keep for future reference

3 Login

1. I cannot log in to the web UI of the switch. What should I do?
FAQ

Step 1 Use an Ethernet cable to connect the computer to one of the ports 1 -
24 of the switch.

Switch

Step 3 Start a web browser (such as Chrome) on the computer, and enter the
default IP address of the switch (default: 10.16.16.168) in the address
bar, and press Enter on the keyboard.

10.16.16.168

Ethernet cable

Computer

Step 4 Enter the login user name and password (both are admin by default)
on the login page of the switch, and click Login.

User Name

Step 2 Set the IP address of Ethernet (or Local Area Connection) of the
computer to the same network segment of the switch’s IP address.
The default IP address of the switch is 10.16.16.168. You can set the
IP address of the computer to 10.16.16.X (X ranges from 2 to 254
excluding 168, and is not occupied) and the subnet mask to
255.255.255.0.

Password

Try the following solutions:
- Check whether the switch is powered on properly: The Power LED indicator is
solid on.
- Check whether the computer is connected to the switch properly with an
Ethernet cable.
- Check whether the IP address of Ethernet (or Local Area Connection) of the
computer is set to 10.16.16.X (X ranges from 2 to 254 excluding 168, and is
not occupied).
- Clear the cache of the web browser or try another web browser.
- Disable the firewall of the computer, or try another computer.
- Check whether only one device with the IP address 10.16.16.168 exists in the
local network.
- If the problem persists, reset the switch and try again.
Reset method: When the SYS LED indicator is blinking, press and hold the
Reset button for about 10 seconds, and then release it when all indicators are
solid on. When the SYS LED indicator blinks again, the switch is restored to
factory settings.
2. I forget the login user name and password when logging in to
the web UI. What should I do?

Step 3 Press Enter twice and enter the user name and password of
the switch (both are admin by default) on the page to enter the
command-line interface of the switch.

English

Forget password

COM1 - PuTTY

Login

Try entering the default login user name and password (both are admin). If you
still fail to log in to the web UI, reset the switch, then use the default user name
and password to log in.

Username: admin
Password:
G5328X

20
16
16
10

3. How do I connect the switch through the Console port?

Tips

255
255
255
0

If you fail to access the above page, please refer to question 1 in FAQ.

After successfully logging in to the web UI of the switch, you can configure the
switch now.

Please operate as follows:
Step 1 Connect the computer and the Console port of the switch with the
included console cable.
Step 2 Run a serial interface connection software (such as PuTTY) on the
computer. Enter 115200 in the Speed box and select Serial as the
Connection type. Then click Open.

Specifications
English

’арактеристики
Русский

Спецификации
Български

Spezifikationen
Deutsch

Specifiche
Italiano

Model
G5328X

Модель
G5328X

Модел
G5328X

Modell
G5328X

Modello
G5328X

24

24

24

24

24

10/100/1000 Mbps
RJ45 port

Порт RJ45 10/100/
1000 Мбит/с

10/100/1000 Mbps
RJ45 порт

10/100/1000 Mbit/s
RJ45-Port

Porta RJ45 10/100/
1000 Mbps

Порт

Port

Porte

Port

Порт

4 porte SFP+ indipendenti

4 независимы SFP+ порта

Порт SFP+ 10000 Мбит/с

4 независими SFP+ порта

Porta SFP+ 10000 Mbps

4 independent SFP+ ports

4 unabhängige SFP+-Ports

10000 Mbit/s SFP+-Port

10000 Mbps SFP+ port

10000 Mbps SFP+ порт

1; Velocità: 115200

Porta console

1; Baud rate: 115200

1; Скорость передачи в бода : 115200

1; Скорост на боуд: 115200

1; Baudrate: 115200

Консольный порт

Console port

Конзолен порт

Konsolen-Anschluss

Store-and-forward

Modalità switching

Со ранение и дальнейшая передача

Режим переключения

Modus wechseln

Store-and-forward

Speichern und weiterleiten

Съ раняване и препращане

Switching mode

Режим на
превключване

Auto invecchiamento, auto apprendimento

Автоматические старение, автоматическое обучение

выполнение

Performance

Prestazioni

Leistung

Automatisches Altern, automatisches Lernen

Auto aging, auto learning

Автоматично навършени, автоматично обучение

Apprendimento degli
indirizzi MAC

Изучение MAC-
адресов

MAC address table
learning

MAC-Adressentabelle
lernen

Таблица с MAC
адреси, обучение

Теˆнически
показатели

16 K

16 K

16 K

16 K

16 K

Таблица MAC-адресов

Таблица с MAC адреси

MAC-Adressentabelle

MAC address table

Tabella degli indirizzi
MAC

440 мм x 179,6 мм x 44 мм

440 mm x 179,6 mm x 44 mm

440 mm x 179,6 mm x 44 mm

Dimensions (L x W x H)

440 mm x 179.6 mm x 44 mm

Размеры (Д ˆ Ш ˆ В)

Размери (Д ˆ Ш ˆ В)

Dimensioni (L x P x A)

Abmessungen (L x B x H)

440 mm x 179,6 mm x 44 mm

Вˆодное напряжение

Вˆодящо напрежение

Input voltage

Tensione di ingresso

Nennspannung

100–240 В перем. тока, 50/60 Гц, 0,7A

100 - 240V AC, 50/60Hz, 0.7A

100 - 240 V CA, 50/60 Hz, 0,7A

100 – 240 V AC, 50/60 Hz, 0,7 A

100 - 240 V AC, 50/60 Hz, 0,7A

Common mode: 6 kV

Обычный режим: 6 kV

Normaler Modus: 6 kV

Modalità comune: 6 kV

Общ режим: 6 kV

Порт RJ45

RJ45 порт

RJ45 port

RJ45-Port

Porta RJ45

Lightning
protection

Common mode: 6 kV ; Differential mode: 4 kV

Обычный режим: 6 kV;Дифференциальный режим: 4 kV

Modalità comune: 6 kV; Modalità differenziale: 4 kV

Общ режим: 6 kV ; Диференциален режим: 4 kV

Normaler Modus: 6 kV; Differentialmodus: 4 kV

Источник питания
Молниезащита

Заˆранване
Мълниезащита

Power supply

Stromversorgung
Blitzschutz

Alimentazione

Protezione
contro i
fulmini

Рабочая среда

Работна среда

Operating environment

Betriebsumgebung

Температура: 0°C - 45°C
Влажность: (10–90%) без конденсации

Температура: 0°C - 45°C
Влажност: (10% – 90%) RH, некондензиращи

Ambiente operativo

Temperature: 0°C - 45°C
Humidity: (10% - 90%) RH, non-condensing

Temperatur: 0°C - 45°C
Luftfeuchtigkeit: (10 % - 90 %) RH, nicht kondensierend

Temperatura: 0°C - 45 °C
Umidità: 10% - 90% UR, senza condensa

Условия ˆранения

Среда за съˆранение

Lagerumgebung

Storage environment

Температура: -40°C - 70°C
Влажность: (5–90%) без конденсации

Ambiente di immagazzinaggio

Температура: -40°C - 70°C
Влажност: (5% – 90%) RH, некондензиращи

Temperatur: -40°C - 70°C
Luftfeuchtigkeit: (5% - 90 %) RH, nicht kondensierend

Temperature: -40°C - 70°C
Humidity: (5% - 90%) RH, non-condensing

Temperatura: -40°C - 70°C
Umidità: (5% - 90%) UR, senza condensa

Скорость передачи информации

Data transmission rate

Datenübertragungsrate

Скорост на предаване на данни

Velocità di trasmissione dati

Ethernet: 10 Mbit/s (Halbduplex)/20 Mbit/s (Vollduplex)
Fast Ethernet: 100 Mbit/s (Halbduplex)/
200 Mbit/s (Vollduplex)
Gigabit Ethernet: 2000 Mbit/s (Vollduplex)
10 Gigabit Ethernet: 20000 Mbit/s (Vollduplex)

Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex)/
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)

Ethernet: 10 Mbps (half duplex) / 20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex) /
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)

Ethernet: 10 Mbps (полудуплексный)/
20 Mbps (полнодуплексный)
Fast Ethernet: 100 Mbps (полудуплексный)/
200 Mbps (полнодуплексный)
Гигабитный Ethernet: 2000 Mbps (полнодуплексный)
10-Гигабитный Ethernet: 20000 Mbps (полнодуплексный)

Ethernet: 10 Mbps (полудуплекс)/
20 Mbps (пълен дуплекс)
Бърз Ethernet: 100 Mbps (полудуплекс)/
200 Mbps (пълен дуплекс)
Гигабитен Ethernet: 2000 Mbps (пълен дуплекс)
10-гигабитен Ethernet: 20000 Mbps (пълен дуплекс)

Transmission media

Übertragungsmedien

Mezzi di trasmissione

Средства передачи

Среда на предаване

Ethernet: CAT3 UTP/STP-Kabel oder höher
Fast Ethernet: CAT5 UTP/STP-Kabel oder höher
Gigabit Ethernet:CAT5e oder CAT6 UTP/STP Kabel
1000Base-SX: MMF
1000Base-LX: MMF oder SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: CAT3 UTP/STP or better
Fast Ethernet: CAT5 UTP/STP or better
Gigabit Ethernet: CAT5e or CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF or SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: Cavo UTP/STP CAT3 o superiore
Fast Ethernet: Cavo UTP/STP CAT5 o superiore
Gigabit Ethernet: Cavo UTP/STP CAT5E o CAT6
1000Base-SX: MMF
1000Base-LX: MMF o SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: Кабель CAT3 UTP/STP или выше
Fast Ethernet: Кабель CAT5 UTP/STP или выше
Gigabit Ethernet: Кабель CAT5E или CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF или SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: CAT3 UTP/STP или по-добре
Бърз Ethernet: CAT5 UTP/STP или по-добре
Гигабитен Ethernet: CAT5e или CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF или SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Standards

Standard di rete

Стандарты

Standards

Стандарти

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

Especificações
Português

Especificaciones
Español

Spécifications
Français

Dane techniczne
Polski

Specificaţii
Română

Modelo
G5328X

Modelo
G5328X

Modèle
G5328X

Model
G5328X

Model
G5328X

24

24

24

24

24

Porta RJ45 10/100/
1000 Mbps

Puerto RJ45 de 10/
100/1000 Mbps

Port RJ45 10/100/
1000 Mbps

Port RJ45 10/100/
1000 Mb/s

Port RJ45 10/100/1
000 Mbps

Porta

Port

Port

Port

Puerto

4 ports SFP+ indépendants

Port SFP+ 10000 Mbps

4 portas SFP+ independentes

4 niezależne porty SFP+

4 porturi SFP+ independente

4 puertos SFP+ independientes

Porta SFP+ 10000 Mbps

Port SFP+ 10000 Mb/s

Port SFP+ 10000 Mbps

Puerto SFP+ de 10000
Mbps

1; Débit en Baud: 115200

Port de la console

1; Taxa de Baud: 115200

Porta da consola

1; Prędkość transmisji: 115200

1; Rată Baud: 115200

Port konsoli

Port consolă

1; Velocidad en baudios: 115200

Puerto de consola

Stockage et transmission

Guardar e reencaminhar

Mode de commutation

Modo de comutação

Zapis-i-wprzód

Tryb przełączania

Store-and-forward

Switching mode

Almacenar y retransmitir

Modo de conmutación

Envelhecimento automático, aprendizagem automática

Auto vieillissement, auto apprentissage

Automatyczna pamięć adresów i chwili rejestracji

Nauka adresów MAC

Desempenho

Wydajność

Performanţă

Rendimiento

Performance

Aprendizagem de
endereços MAC

Apprentissage des
adresses MAC

Auto aging, auto learning

Vencimiento automático, aprendizaje automático

MAC address table
learning

Aprendizaje de
direcciones MAC

16 K

Tabela adresów MAC

16 K

16 K

16 K

16 K

MAC address table

Tabla de direcciones MAC

Tabela de endereços
MAC

Tableau des adresses
MAC

440 mm x 179,6 mm x 44 mm

Wymiary (dł. x szer. x wys.)

Dimensões (C x L x A)

440 x 179,6 x 44 mm

440 mm x 179,6 mm x 44 mm

440 mm x 179,6 mm x 44 mm

440 mm x 179,6 mm x 44 mm

Dimensiuni (L x l x Î)

Dimensiones (L x An x Al)

Dimensions (L x W x H)

100 - 240V AC, 50/60Hz, 0,7A

Napięcie wejściowe

100 - 240 V c.a., 50/60 Hz, 0,7 A

100-240V AC, 50/60Hz, 0,7 A

100-240V AC, 50/60Hz, 0,7A

100 - 240 V CA, 50/60 Hz, 0,7 A

Tensiune de intrare

Voltaje de entrada

Tension d'entrée

Tensão de entrada

Tryb wspólny: 6 kV

Port RJ45

Mod obişnuit: 6 KV

Modo comum: 6 kV

Mode commun : 6 kV

Modo común: 6 kV

Porta RJ45

Port RJ45

Puerto RJ45

Port RJ45

Proteção
contra raios

Protección
contra rayos

Tryb wspólny: 6 kV; Tryb różnicowy: 4 kV

Zasilanie

Mod obişnuit: 6 KV; Mod diferenţial: 4 KV

Modo comum: 6 kV; Modo diferencial: 4 kV

Mode commun : 6 kV; Mode différentiel : 4 kV

Modo común: 6 kV; Modo diferencial: 4 kV

Fonte de energia

Sursa de alimentare

Fuente de alimentación

Alimentation électrique

Ochrona
przed
piorunami

Protection
contre la
foudre

Protecţie
împotriva
descărcărilor
electrice

Entorno de funcionamiento

Środowisko pracy

Environnement opérationnel

Ambiente operacional

Mediu de funcţionare

Température : 0°C - 45°C
Humidité :(10 % - 90 %) HR, non-condensant

Temperatura: 0-45 °C
Humedad: 10 %-90 % HR, sin condensación

Temperatura: 0°C - 45°C
Umiditate: (10% - 90%) umiditate relativă, fără condens

Temperatura: 0°C - 45°C
Humidade: (10% - 90%) de HR, sem condensação

Temperatura: 0°C - 45°C
Wilgotność: (10–90%) wilgotności względnej,
bez kondensacji

Entorno de almacenamiento

Environnement de stockage

Ambiente de armazenamento

Température : -40°C - 70°C
Humidité : (5 % - 90 %) HR, non-condensant

Temperatura: -40-70 °C
Humedad: 5 %-90 % HR, sin condensación

Mediu de depozitare

Temperatura: -40°C - 70°C
Umiditate: (5% - 90%) umiditate relativă, fără condens

Temperatura: -40°C - 70°C
Humidade: (5% - 90%) de HR, sem condensação

Środowisko przechowywania

Temperatura: -40°C - 70°C
Wilgotność: (5–90%) wilgotności względnej, bez kondensacji

Taux de transmission des données

Velocidad de transmisión de datos

Taxa de transmissão de dados

Viteză de transmisie a datelor

Szybkość transmisji danych

Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Ethernet rápida: 100 Mbps (half duplex)/
200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
10 Gigabit Ethernet: 20000 Mbps (full duplex)

Ethernet: 10 Mbps (dúplex medio)/
20 Mbps (dúplex completo)
Fast Ethernet:100 Mbps (dúplex medio)/
200 Mbps (dúplex completo)
Gigabit Ethernet: 2000 Mbps (dúplex completo)
10 Gigabit Ethernet: 20000 Mbps (dúplex completo)

Ethernet : 10 Mbit/s (semi duplex)/
20 Mbit/s (duplex intégral)
Fast Ethernet : 100 Mbit/s (semi duplex)/
200 Mbit/s (duplex intégral)
Gigabit Ethernet : 2000 Mbit/s (duplex intégral)
10 Gigabit Ethernet : 20000 Mbit/s (duplex intégral)

Ethernet: 10 Mbps (semi duplex)/
20 Mbps (duplex complet)
Fast Ethernet: 100 Mbps (semi duplex)/
200 Mbps (duplex complet)
Ethernet Gigabit: 2000 Mbps (duplex complet)
10 Ethernet Gigabit: 20000 Mbps (duplex complet)

Sieć Ethernet: 10 Mb/s (półdupleks) /
20 Mb/s (pełny dupleks)
Szybka sieć Ethernet: 100 Mb/s (półdupleks) /
200 Mb/s (pełny dupleks)
Gigabitowa sieć Ethernet: 2000 Mb/s (pełny dupleks)
10 Gigabit Ethernet: 20000 Mb/s (pełny dupleks)

Support de transmission

Medios de transmisión

Meios de transmissão

Mediu de transmitere

Środki transmisji

Ethernet: Cabo CAT3 UTP/STP ou superior
Ethernet rápida: Cabo CAT5 UTP/STP ou superior
Gigabit Ethernet: Cabo CAT5E ou CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF ou SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: Cable CAT3 UTP/STP o superior
Fast Ethernet: Cable CAT5 UTP/STP o superior
Gigabit Ethernet: CAT5e o UTP/STP CAT6
1000Base-SX: MMF
1000Base-LX: MMF o SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet : CAT3 UTP/STP ou supérieur
Fast Ethernet : CAT5 UTP/STP ou supérieur
Gigabit Ethernet : CAT5e ou CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF ou SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Sieć Ethernet: Kabel CAT3 UTP/STP lub lepszy
Szybka sieć Ethernet: Kabel CAT5 UTP/STP lub lepszy
Gigabitowa sieć Ethernet: Kabel CAT5e lub CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF lub SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: Cablu CAT3 UTP/STP sau o versiune mai nouă
Fast Ethernet: Cablu CAT5 UTP/STP sau o versiune
mai nouă
Ethernet Gigabit: CAT5e sau CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF sau SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Normas

Estándares

Normes

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

Standardy

Standarde

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

Specifikáció
Magyar

Özellikler
Türkçe

Safety and statement

RECYCLING

Modell
G5328X

Model
G5328X

G5328X

24

24

CE Mark Warning

10/100/1000 Mb/s
RJ45 port

10/100/1000 Mbps
RJ45 portu

portok

Port

4 bağımsız SFP+ portu

10000 Mbps SFP+ portu

4 szabad SFP+ port

SFP+

10000 Mb/s SFP+ port

This product bears the selective sorting symbol for Waste electrical and electronic
equipment (WEEE). This means that this product must be handled pursuant to
European directive 2012/19/EU in order to be recycled or dismantled to minimize its
impact on the environment.

1; Baud hızı: 115200

1; átviteli sebesség 115200

Konsol portu

konzol csatlakozó felület

This is a Class A product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
The mains plug is used as disconnect device, the disconnect device shall remain
readily operable.

Sakla ve gönder

Anahtarlama modu

Tárol és továbbít

User has the choice to give his product to a competent recycling organization or to
the retailer when he buys a new electrical or electronic equipment.

Kapcsolási mód

Otomatik yaşlanma, otomatik öğrenme

MAC adres öğrenme

Performans

Működés

Automatikus elhasználódás, öntanulás

MAC címtáblázat
tanulás

16 K

MAC adres tablosu

16 K

MAC cím táblázat

NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation
interference, it is recommended to use a shielded RJ45 cable.

440 mm x 179,6 mm x 44 mm

Boyutlar (B x E x Y)

440 mm x 179,6 mm x 44 mm

Méretek (H x Sz x M)

100 - 240V AC, 50/60 Hz, 0,7A

Giriş Gerilimi

100-240 V váltóáram, 50/60Hz 0,7 A

Bemeneti feszültség

Ortak mod: 6 kV

RJ45 portu

Közös üzemmód: 6 kV

RJ45 port

Yıldırım
koruması

Villámcsapás
védelem

Ortak mod: 6 kV; Diferansiyel mod: 4 kV

Güç kaynağı

Közös üzemmód: 6 kV; Differenciál üzemmód: 4 kV

Tápellátás

Çalışma ortamı

Működési környezet

Sıcaklık: 0°C - 45°C
Nem: (%10 - %90) RH, yoğuşmasız

Hőfok: 0°C - 45°C
Páratartalom: 10 - 90% RH, nem kicsapódó

Depolama ortamı

Tárolási környezet

Sıcaklık: -40°C - 70°C
Nem: (%5 - %90) RH, yoğuşmasız

Hőfok: -40°C - 70°C
Páratartalom: 5 - 90% RH, nem kicsapódó

Adatátviteli sebesség

Veri iletim hızı

Ethernet: 10 Mb/s (fél duplex)/20 Mb/s (teljes duplex)
Fast Ethernet: 100 Mb/s (fél duplex)/
200 Mb/s (teljes duplex)
Gigabit Ethernet: 2000 Mb/s (teljes duplex)
10 Gigabit Ethernet: 20000 Mb/s (teljes duplex)

Ethernet: 10 Mbps (yarı çift yönlü) /
20 Mbps (tam çift yönlü)
Fast Ethernet: 100 Mbps (yarı çift yönlü) /
200 Mbps (tam çift yönlü)
Gigabit Ethernet: 2000 Mbps (tam çift yönlü)
10 Gigabit Ethernet: 20000 Mbps (tam çift yönlü)

FCC Statement
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference
in which case the user will be required to correct the interference at his own expense.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

Átviteli közeg

İletim Ortamları

Ethernet: CAT3 UTP/STP vagy gyorsabb kábel
Fast Ethernet: CAT5 UTP/STP vagy gyorsabb kábel
Gigabit Ethernet: CAT5e vagy CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF vagy SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Ethernet: CAT3 UTP/STP veya daha iyisi
Fast Ethernet: CAT5 UTP/STP veya daha iyisi
Gigabit Ethernet: CAT5e veya CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF veya SMF
10GBase-SR: MMF
10Gbase-LR: SMF

Caution!
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.

Szabványok

Standartlar

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3ae, IEEE 802.1d, IEEE 802.1p,
IEEE 802.1q, IEEE 802.1w, IEEE 802.1s

NOTE: (1) The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications to this equipment. (2) To avoid unnecessary radiation
interference, it is recommended to use a shielded RJ45 cable.

Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

Aruba 2930F JL262A

9 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

CUDY GS2008PS2

2 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-1210-10MP/F3A

12 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-1210-10MP/F3A

12 стр.
Сетевое оборудование / Профессиональное сетевое оборудование / Коммутаторы

D-Link DGS-3130-54TS/B1A

25 стр.