Инструкция кондиционер настенный сплит-система Centek CT-65J07

Страница 36 (стр. 36 из 48)

Бренд: Centek

Страница 36 документа Кондиционер настенный сплит-система Centek CT-65J07. Раздел: Кондиционеры (сплит-системы). Бренд: Centek.

Текст страницы

MOUNTING PANEL INSTALLATION
Place the metal mounting panel of the indoor unit on the wall
according to Fig. 4.
At least 4 mounting holes should be provided in the wall for the secure
fastening of the mounting panel. Ensure that the mounting panel is
installed horizontally.
Drill the hole in the wall as shown in Fig. 5. The hole of 70 mm diameter
should be slightly inclined towards the outside.
Cut a length of PVC tube, slightly shorter than the wall thickness and
with slightly slanted edges and insert it into the hole (Fig. 5).

OUTDOOR UNIT LOCATION
– Away from heat sources, flammable gases and fumes.
– In a well-ventilated space protected from rain, snow and direct
sunlight.
– Where AC operation or the water exiting from the drain tube cannot
disturb your neighbors.
– The mounting location shall be easily accessible for maintenance.
– The outdoor unit should be mounted on a stable and secure base
which will not result in increased noise or vibrations.
– To ensure high efficiency check that the front, rear, right and left
sides of the unit are free from obstructions.
– Check the installation distances as shown in Fig. 2.

left-hand side
Right side

Не менее 10 см

not less than 10 cm

not less
than 2 m

Не менее 2 м

Не менее

15 см

Не менее

15 см

Выход воздуха

air outlet

Вход воздуха

air inlet

barrage

Figure 4

Не менее 2,3 м

not less
than 2,3 m

premises
wall
premises

заграждение

outdoor unit

Внешний блок

not less than 15 cm

not less than 15 cm

pvc tube

Figure 2

wall cover

slight slope

HEIGHT DIFFERENCE
Ensure that the mounting elevation (height) difference between the
indoor and outdoor units does not exceed 5 meters (Fig. 3).
If the pipeline length is between 7 and 15 m an additional refrigerant
charge will be required in accordance with Table 1.

Figure 5

height difference
indoor unit

Разность высот
Внутренний блок

Внешний блок

indoor unit
outdoor unit

Внутренний блок

Figure 3

INDOOR UNIT INSTALLATION
You can lead the connecting tubes out of the indoor unit on both sides
as shown in Fig. 7. Choose the most appropriate side.
1. Tube connections on the right side
– Pull the hose from the lower part of the chassis and connect the
drain tube.
– Securely fasten the hose connection.
– Connect the signal cable to the inner unit (do not connect the power
supply).
– Place the connecting tubes, cable and drain hose as shown in Fig. 6,
then connect the drain hose to the drain port. The drain hose should
extend with a slight downward gradient. Bundle the connecting
tubes, cables and drain hose together with vinyl tape. Ensure a
sufficient space between the drain hose and the ground. Do not put
the drain tube into water or a ditch.

Table 1

Quantity of additional refrigerant
(g/m)

Min. Tube
length
(m)

< 12000 BTU/h
> 18000 BTU/h

Maximum allowable tube
length without additional
refrigerant charge
(m)

Maximum allowable
tube length
Maximum allowable
mounting height
difference between the
indoor and outdoor units

2
5
models:
07/12 - 25 m,
18/30 - 30 m

models:
07/12 - 12 m,
18/30 - 18 m
20
30

35