Текст страницы
EN
LASER DISTANCE METER
LASER DISTANCE METER
EN
Vector 100 CONDTROL
Vector 100 CONDTROL
User manual
User manual
Congratulations on your purchase of laser distance meter Vector 100 CONDTROL.
Safety instructions can be found in the end of this user manual and should be
carefully read before you use the product for the first time.
DELIVERY PACKAGE
The delivery package includes:
1. Laser distance meter – 1pc.
2. Carry pouch with a strap - 1 pc.
3. User manual - 1 pc.
5. USB charger - 1 pc.
TECHNICAL SPECIFICATIONS
Measuring range*
0.05–100 m
Measuring accuracy **
± 1.5 mm
Smallest unit displayed
1 mm
SAFETY REGULATIONS
The user manual should be read carefully before you use the product for the first
time. Unintended use of the product can be dangerous for human’s health and
cause serious injury. Keep this user manual. If the product is given to somebody
for temporary use, be sure to enclose user manual to it.
- Do not misuse the product
- Do not remove warning signs and protect them from abrasion, because they
contain information about safe operation of the product.
The device belongs to laser product class 2 in accordance with EN60825-1.
Display backlight
+
Reference point
Front, rear, tripod, end-piece
Continuous measurement (tracking)
+
Max./min. value
+
Laser radiation!
Do not stare into beam
Class 2 laser
<1 mW 635nm
EN60825-1: 2007-03
Addition/subtraction
+
Area/wall surface/volume
+
Calculation of horizontal distance by tilt sensor
+
Calculations by Pythagoras’ theorem
+
Point to point measurement
+
Bluetooth
+
Timer
+
- Do not look into the laser beam or its reflection, with unprotected eye or
through an optical instrument. Do not point the laser beam at people or animals
without the need. You can dazzle them.
- To protect your eyes close them or look aside.
- It is prohibited to disassemble or repair the product yourself. Entrust product
repair to qualified personnel and use original spare parts only.
- Do not use the product in explosive environment, close to flammable materials.
- Avoid heating the batteries to avoid the risk of explosion and electrolyte
leakage. In case of liquid contact with skin, wash it immediately with soap and
water. In case of contact with eyes, flush with clean water during 10 minutes and
consult the doctor.
Digital vial
+
Memory
up to 30 values
Laser
Class II, 635nm, <1 mW
Operating temperature
0 °С ... +40 °С
Storage temperature
–20 °С ... +60 °С
INTENDED USE
Laser distance meters Vector 100 is intended to measure distance, to calculate
area and volume of measured objects, perform calculations by tilt sensor
and Pythagoras’ Theorem, point to point measurements, store results of
measurement/calculation in memory and also transmit via Bluetooth. The
product is suitable for use at both indoor and outdoor building areas.
Dust and water protection
IP54
5
4