Инструкция лазерный нивелир CONDTROL Fliesen 3D Laser

Cross line laser EN (стр. 1 из 3)

Бренд: CONDTROL

Страница 1 документа Лазерный нивелир CONDTROL Fliesen 3D Laser. Раздел: Лазерные нивелиры, уровни. Бренд: CONDTROL.

Текст страницы

WARRANTY

Cross line laser EN

Kreuzlinienlaser DE

Vertical line
Use a plumb bob as a reference of a vertical line. Put the laser
level at 1.5m distance from the plumb bob. (Fig. E).
1. Move the switch bar on position ON, and align vertical laser
line with the low point of plumb bob.
2. If deviation between the laser line and the plumb line
exceeds 0,3 mm per 1m of plumb bob length (for a 2.5m plumb
bob deviation shouldn’t exceed 0.7 mm) – please contact the
service center.

Лазерный нивелир RU

DELIVERY PACKAGE
Laser level – 1 pc.
Cable tie – 1 pc.
Battery (3.7V 3000 mAh Li-ion) – 1 pc.
Adapter for alkaline batteries – 1 pc.
Lifting platform – 1 pc.
Charging cable – 1 pc.
Laser intensive glasses - 1 pc.
Magnetic target board – 1 pc.
User manual – 1 pc.
Plastic case – 1 pc.

ACCURACY CHECK
Horizontal line
Check of horizontal line is carried out by using 2 walls located
opposite each other at a 5m distance.
1 Put the laser level to one of the walls as close as possible
(Figure A). Move the switch bar to position ON and switch
on both vertical and horizontal planes. Rotate the laser level
so that laser emitters are located opposite to the near wall
and laser lines cross each other. Mark location of laser lines
crossing as А1. Mark location of laser lines crossing on another
wall as B1.

E

PRODUCT DESCRIPTION
Laser level Fliesen 3D Laser CONDTROL is designed for
projecting and controlling of vertical and horizontal planes
and lines.
The laser level has 2 operating modes:
- Locked compensator, to project inclined planes and lines;
- Automatic leveling, which allows to automatically
compensate irregularities within self-leveling range of ±5°.
Pulse mode allows to increase working range of the laser level
by using the laser receiver or to work when laser is hard to
define in bright lighting conditions.
This laser level is suitable for use at both indoor and outdoor
building areas

A

2

BEFORE START OPERATION
Power supply
The laser level is powered by a 3.7V 3000 mAh Li-ion
rechargeable battery included in the delivery package.

1

6

1.5m

5m

Install/replace batteries/charge the Li-ion battery
Install the battery in the battery compartment, observing the
polarity.
Use only the battery included in the delivery package.
If the power indicator on the control panel becomes red,
charge the battery.
The battery should be charged in the following way:
1) Remove the battery from the device.
2) Connect the charger to the power source with a charging
cable, included in the delivery package.
The battery charging time depends on the current of the used
adapter:

1
1 5
1

8
7

2. Rotate the laser level by 90°, measure deviation of a laser
line from point В1 (Figure B). If deviation exceeds 1.5 mm –
please contact the service center.

All CONDTROL GmbH devices go through post-production
control and are governed by the following warranty terms. The
buyer’s right to claim about defects and general provisions of
the current legislation do not expire.
1) CONDTROL GmbH agrees to eliminate all defects in the
device, discovered during the warranty period, that represent
the defect in material or workmanship in full volume and at its
own expense.
2) The warranty period is 24 months and starts from the date
of purchase by the end customer (see the original supporting
document).
3) The warranty doesn’t cover defects resulting from wear
and tear or improper use, malfunction of the device caused
by failure to observe the instructions of this user manual,
untimely maintenance and service and insufficient care, the
use of non-original accessories and spare parts. Modifications
in design of the device relieve the seller from responsibility
for warranty works. The warranty does not cover cosmetic
damage, that doesn’t hinder normal operation of the device.
4) CONDTROL GmbH reserves the right to decide on
replacement or repair of the device.
5) Other claims not mentioned above, are not covered by the
warranty.
6) After holding warranty works by CONDTROL GmbH warranty
period is not renewed or extended.
7) CONDTROL GmbH is not liable for loss of profit or
inconvenience associated with a defect of the device, the
rental cost of alternative equipment for the period of repair.

B

#
Current
Charging time
1
500 mA
6 hours
2
1000 mA
3 hours
3
2A
1.5 hours
Note: It is forbidden to use adapters with an output voltage of
more than 5V! It may lead to damage of the battery.

This warranty applies to German law except provision of the
United Nations Convention on contracts for the international
sale of goods (CISG).
In warranty case please return the device to retail seller or
send it with defect description to the following address:

CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany

ws

3) As soon as the charging time runs out, disconnect the
charger and put the battery in the battery compartment.
Adapter for alkaline batteries is included in the delivery
package. Insert alkaline batteries (type AA 1.5V) in adapter
and continue to use the laser level, while Li-ion battery is being
charged.

Fliesen 3D Laser

3
4

OPERATION
Install the device on a firm and stable surface or tripod.
Move the switch bar to select the required operation mode:

1– Laser beam exit windows
2 – Control panel
3 – Battery door
4 – Tripod thread 1/4’’
5 – Switch bar
6 – Magnets for fixing on vertical structures
7 – Hole for fixing by the cable tie
8 – Hole for fixing on a screw/nail

EN User manual 1
DE Bedienungsanleitung 2
RU Руководство по эксплуатации 3

3. Repeat actions described in point 2 twice, rotating the laser
level in one direction.
4. Install the laser level closer to the opposite wall. Mark
location of laser lines crossing as В2 (points В1, В2 must be
located at the same vertical) (Figure C).

Control panel

4

1) Automatic leveling
Move the switch bar to position ON.
The laser level will switch on. LED indicator is green.
Upper H-line is on.

C

Short press to switch on required laser lines.

3
5

Fliesen 3D Laser

Cross line laser EN

Short press to switch on/off the pulse mode. When

1

2

User manual

pulse mode is on, LED indicator is green.
Move the switch bar to position OFF to switch off the laser
level.
When the battery is low, LED indicator is flashing red.

Congratulations on your purchase of laser level CONDTROL
Fliesen 3D Laser.
Safety regulations can be found in this user manual and should
be carefully read before you use the device for the first time.

2) Inclined lines
The switch bar is in position OFF.

Press and hold during 3 seconds to switch on the laser.

1 - Switch on/off the laser lines
2 - Switch on/off the pulse mode
3 - Power indicator
4 - Indicator of inclined planes mode
5 - Indicator of pulse mode

CARE AND MAINTENANCE
Attention! This laser level is a precise optic-mechanical device
and requires careful handling. Before starting work, as well
as after mechanical influences (falling, bumps), check the
accuracy of the device.
Observation of the following recommendations will extend
the life of the device:
- Store the device, spare parts and accessories away from
children and unauthorized people.
- Transport the device with locked compensator only.
- Protect the device from bumps, falls, and excessive vibration;
do not let moisture, construction dust and foreign objects get
inside the device.
- In case moisture gets inside the device, first of all, remove the
batteries and then contact the service center.
- Do not store or use the device for a long time in high humidity
conditions.
- Check the accuracy of the device occasionally (check the
paragraph «Accuracy check»).
- Clean the device with a soft wet cloth. Do not use harsh
chemicals, cleaning solvents or cleaning agents.
- Wipe the laser aperture with a soft lint-free cloth and
isopropyl alcohol.
- Remove the Li-ion battery or alkaline batteries from the
device before connecting the charger, otherwise the device
may fail.
Failure to observe the following rules may lead to electrolyte
leakage from the batteries and failure of the device:
- Remove the batteries from the device, if it’s not used for a
long time.
- Do not leave discharged batteries in the device.
- Avoid heating the batteries to avoid the risk of explosion and
electrolyte leakage. In case of liquid contact with skin, wash
it immediately with soap and water. In case of contact with
eyes, flush with clean water during 10 minutes and consult the
doctor.

Upper H-line is on. Laser line is flashing every 5 seconds. LED

5. Rotate the laser level by 180°and mark location of laser lines
crossing on the opposite wall as A2 (points A1, A2 must be
located at the same vertical) (Figure D).
6. Measure distances dA, dB between points А1, А2 and В1,
В2 accordingly (Figure D). If difference between values dA, dB
exceeds 3 mm – please contact the service center.

TECHNICAL SPECIFICATIONS

indicator is red.

UTILIZATION

D

Working range/
with receiver*
20 m/40 m

Long press during 3 seconds to switch on required

SAFETY INSTRUCTIONS
The user manual should be read carefully before you use the
device for the first time. Unintended use of the device can
be dangerous for human’s health and cause serious injury.
Keep this user manual. If the device is given to somebody for
temporary use, be sure to enclose user manual to it.
- Do not misuse the device.
- Do not remove warning signs and protect them from
abrasion, because they contain information about safe
operation of the device.

Self-levelling accuracy
±0.3 mm/m

laser lines.

Expired tools, accessories and package should be passed
for waste recycle. Please send the product to the following
address for proper recycle:

Self-levelling range
± 5°

After all combinations of lines are switched on, the next long

Working temperature
-10°C ... +50°C

press will switch off the laser level.

Storage temperature
-20°C ... +70°C

Laser radiation! Do not stare into beam
Class 2 laser
<1 mW 520 nm
EN60825-1: 2007-03

Relative humidity
90%

Press and hold during 3 seconds to switch on/off the

CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany

pulse mode. When pulse mode is on, LED indicator is

Dust and water
protection rate
IP54

green.

Thread for mounting
on a tripod
1/4’’

Attention: please do accuracy check for each horizontal plane
separately.

Laser type
Class II 520nm < 1 mW

Do not throw the product in municipal waste!
According to European directive 2002/96/ЕC expired
measuring tools and their components must be collected
separately and submitted to environmentally friendly recycle
of wastes.

Battery
3.7V 3000 mAh Li-ion
rechargeable

Dimensions
112x64x116 mm

Weight
- with battery
- without battery
0.42 kg
0.35 kg

* The working range may differ from the declared depending
on the lighting conditions. on the lighting conditions.

Note: To increase the operating time and avoid the risk of
unintentional blinding switch on the laser only before start
operation.
If operated near objects or airflows different from the
environment temperature the laser line may tremble due to
heterogeneity of the atmosphere. The longer the distance, the
more trembling can be observed.
The width of the laser line increases with the increasing of the
operating distance. The marking should be made along the
axis of the laser line. For maximum accuracy, use the middle
portion of the laser line.
It should be noted that the shape of the laser line on the
object’s surface (e.g. walls, ceilings) depends on the curvature
and slope of the surface relative to the laser plane.

1

- Do not look into the laser beam or its reflection, with
unprotected eye or through an optical instrument. Do not
point the laser beam at people or animals without the need.
You can dazzle them.
- To protect your eyes close them or look aside.
-Always install the product in such a way, so that the laser line
is below or above the eye level.
- Do not let unauthorized people enter the zone of product
operation.
- Store the product beyond reach of children and unauthorized
people.
- It is prohibited to disassemble or repair the product yourself.
Entrust product repair to qualified personnel and use original
spare parts only.
- Do not use the product in explosive environment, close to
flammable materials.
- Avoid heating the batteries to avoid the risk of explosion and
electrolyte leakage. In case of liquid contact with skin, wash
it immediately with soap and water. In case of contact with
eyes, flush with clean water during 10 minutes and consult
healthcare practitioner.

Инструмент и стройка / Электроинструменты / Измерительные инструменты / Лазерные инструменты / Лазерные нивелиры, уровни

4010-13-AL Уровень лазерный (RU)

23 стр.
Инструмент и стройка / Электроинструменты / Измерительные инструменты / Лазерные инструменты / Лазерные нивелиры, уровни

4010-13-AL Уровень лазерный (RU)

23 стр.
Инструмент и стройка / Электроинструменты / Измерительные инструменты / Лазерные инструменты / Лазерные нивелиры, уровни

ADA Cube 3-360 Basic Edition

28 стр.
Инструмент и стройка / Электроинструменты / Измерительные инструменты / Лазерные инструменты / Лазерные нивелиры, уровни

ADA Cube 3-360 GREEN Basic Edition

28 стр.
Инструмент и стройка / Электроинструменты / Измерительные инструменты / Лазерные инструменты / Лазерные нивелиры, уровни

ADA Cube 3-360 GREEN Professional Edition

28 стр.