Текст страницы
Format Unit (F7h)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
0
0
0
1
0
0
0
1
Error
…See Below…
Sector Count
-
-
-
-
-
-
-
-
Sector Count
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Device/Head
1
L
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
1
1
1
0
1
1
1
Status
…See Below…
Error Register
Status Register
7
8
9
10
3
2
1
0
7
6
5
4
3
2
1
0
CRC UNC
0
IDN
0
ABT T0N AMN
BSY RDY
DF
DSC DRQ COR IDX ERR
0
V
0
V
0
V
0
0
0
V
0
V
0
0
-
V
Table 111 Format Unit Command (F7h)
The Format Unit command initializes all user data sectors after merging reassigned sector location into the defect
information of the device and clearing the reassign information. Both new reassign information and new defect
information are available right after command completion of this command. Previous information of reassign and
defect are erased from the device by executing this command.
Note that the Format Unit command initializes from LBA 0 to Native MAX LBA regardless of setting by Initialize
Device Parameter (91h) command, Device Configuration Overlay, or Set Max Address (F9h) command, so the
protected area defined by these commands is also initialized.
Security Erase Prepare (F3h) commands should be completed just prior to the Format Unit command. If the device
receives a Format Unit command without a prior Security Erase Prepare command, the device aborts the Format
Unit command.
All values in Feature register are reserved, and any values other than 11h should not be put into Feature register.
This command does not request to data transfer.
Command execution time depends on drive capacity. To determine command timeout value, Word 89 of Identify
Device data should be referred.
154