Инструкция LFF (3.5") Серверный HDD WD Ultrastar DC HC310 HUS726T4TAL5204

Set Power Condition Timer Subcommand (стр. 264 из 326)

Бренд: LFF

Страница 264 документа LFF (3.5") Серверный HDD WD Ultrastar DC HC310 HUS726T4TAL5204. Раздел: Western Digital. Бренд: LFF.

Текст страницы

Set Power Condition Timer Subcommand

Command Block Output Registers
Command Block Input Registers

Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0

Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-

Feature
0
1
0
0
1
0
1
0
Error
…See Below…

Sector Count
V
V
V
V
V
V
V
V
Sector Count
-
-
-
-
-
-
-
-

Sector Number
V
-
V
V
0
0
1
0
Sector Number
-
-
-
-
-
-
-
-

Cylinder Low
V
V
V
V
V
V
V
V
Cylinder Low
-
-
-
-
-
-
-
-

Cylinder High
V
V
V
V
V
V
V
V
Cylinder High
-
-
-
-
-
-
-
-

Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-

Command
1
1
1
0
1
1
1
1
Status
…See Below…

Error Register
Status Register

7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0

CRC UNC
0
IDN
0
ABT T0N AMN
BSY RDY
DF
DSC DRQ COR IDX ERR

0
0
0
0
0
V
0
0
0
V
0
-
-
0
-
V

Table 217 Set Power Condition Timer Subcommand

On successful completion of this EPC subcommand, the device updates the Power Conditions log for the selected
and supported Power Condition as follows:

1) copy the Timer field to the Current Timer Settings field;

2) if Enable is set to one and the Timer field is non-zero, then enable the Current Timer;

3) if Enable is set to one and the Timer field is zero, then disable the Current Timer;

4) if Enable is cleared to zero, then disable the Current Timer; and

5) if Save is set to one and the Power Condition settings are savable, then:

A) copy the Current Timer Settings field to the Saved Timer Settings field; and

B) copy the Current Timer Enabled field to the Saved Timer Enabled field.

264
Western Digital Ultrastar DC HC310 SATA Product Manual