Disable the EPC Feature Subcommand

Command Block Output Registers
Command Block Input Registers

Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0

Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-

Feature
0
1
0
0
1
0
1
0
Error
…See Below…

Sector Count
-
-
-
-
-
-
-
-
Sector Count
-
-
-
-
-
-
-
-

Sector Number
-
-
-
-
0
1
0
1
Sector Number
-
-
-
-
-
-
-
-

Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-

Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-

Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-

Command
1
1
1
0
1
1
1
1
Status
…See Below…

Error Register
Status Register

7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0

CRC UNC
0
IDN
0
ABT T0N AMN
BSY RDY
DF
DSC DRQ COR IDX ERR

0
0
0
0
0
V
0
0
0
V
0
-
-
0
-
V

Table 220 Disable the EPC feature subcommand

On successful completion of this EPC subcommand, the device:

a) stop all EPC timers

b) disables the EPC feature set; and

c) clears IDENITFY DEVICE data word 120 bit 7 to zero.

If the EPC feature set is disabled, then the EPC feature set remains disabled across all resets (i.e., power-on reset,
hardware reset, and software reset).

Output Parameters To The Device

Sector Number
bit
Description

7-4 Reserved
3-0 5h Disable the EPC feature subcommand (See Table 73)

Error Output

If the Extended Power Condition feature set is disabling, not supported then the device returns command aborted.