Key
Code
Qual
Description
Status Field
Error Field
B
S
Y

R
D
Y

D
F

N
A

R
E
Q

A
L
G

S
D
A

E
R
R

C
R
C

U
N
C

O
B
S

I
D
N

O
B
S

A
B
T

O
B
S

C
C
T
6
29
07
I_T Nexus Loss Occurred
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
01
Mode Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
02
Log Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
03
Reservations Preempted
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
04
Reservations Released
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
05
Registrations Preempted
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
09
Capacity Data Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2A
10
Timestamp Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
2F
00
Commands Cleared by Another Initiator
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

6
2F
01
Commands Cleared by Power Loss
Notification

6
3F
01
Microcode has been changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
3F
02
Primary FW image is degraded - booting
from secondary

6
3F
03
Inquiry Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

6
3F
05
Device Identifier Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0

7
20
02
Access Denied
0 1 0 1 0 0 0 1 0 v 0 0 0 v 0 0

7
27
08
Zone Is Read Only
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

7
2C
0E
Zone Is Offline
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

7
2C
12
Zone Is Inactive
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

7
55
0E
Insufficient Zone Resources
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

9
ED
00
Dataeye Physical Layer Test Failure
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

9
EE
00
Dataeye Physical Layer Test Interrupted
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

B
00
00
Internal Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

B
0C
0E
Media Multiple WRITE Error
0 1 0 1 0 0 0 1 0 0 0 1 0 0 0 0

B
0E
01
Information Unit Too Short
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0

B
0E
02
Information Unit Too Long
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0

0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0

B
10
00
Aborted Command - End-to-End T10
Error

0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0

B
10
01
Aborted Command - End-to-End Guard
Check

0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0

B
10
02
Aborted
Command
-
End-to-End
Application Tag Check

0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0

B
10
03
Aborted
Command
-
End-to-End
Reference Tag Check

0 1 0 1 0 0 0 1 0 0 0 1 0 0 0 0

B
11
03
Aborted Command - OCT Timeout In
Recovery

B
26
00
Write/Erase/Read Parameter Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

B
2E
00
Write/Erase/Read Parameter Retry Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

B
2E
02
SCT Read or Write Timeout
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0

B
3F
0F
Aborted
Command
-
Echo
Buffer
Overwritten

B
44
00
Internal Target Failure
0 1 v 1 0 0 0 1 v v 0 v 0 v 0 0

B
47
01
Data Phase CRC Error
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0

B
4B
00
Data Phase Error
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0

356