Текст страницы
Key
Code
Qual
Description
Status Field
Error Field
B
S
Y
R
D
Y
D
F
N
A
R
E
Q
A
L
G
S
D
A
E
R
R
C
R
C
U
N
C
O
B
S
I
D
N
O
B
S
A
B
T
O
B
S
C
C
T
6
29
07
I_T Nexus Loss Occurred
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
01
Mode Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
02
Log Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
03
Reservations Preempted
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
04
Reservations Released
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
05
Registrations Preempted
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
09
Capacity Data Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2A
10
Timestamp Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
2F
00
Commands Cleared by Another Initiator
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
6
2F
01
Commands Cleared by Power Loss
Notification
6
3F
01
Microcode has been changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
3F
02
Primary FW image is degraded - booting
from secondary
6
3F
03
Inquiry Parameters Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
6
3F
05
Device Identifier Changed
0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0
7
20
02
Access Denied
0 1 0 1 0 0 0 1 0 v 0 0 0 v 0 0
7
27
08
Zone Is Read Only
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
7
2C
0E
Zone Is Offline
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
7
2C
12
Zone Is Inactive
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
7
55
0E
Insufficient Zone Resources
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
9
ED
00
Dataeye Physical Layer Test Failure
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
9
EE
00
Dataeye Physical Layer Test Interrupted
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
B
00
00
Internal Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
B
0C
0E
Media Multiple WRITE Error
0 1 0 1 0 0 0 1 0 0 0 1 0 0 0 0
B
0E
01
Information Unit Too Short
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0
B
0E
02
Information Unit Too Long
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0
0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0
B
10
00
Aborted Command - End-to-End T10
Error
0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0
B
10
01
Aborted Command - End-to-End Guard
Check
0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0
B
10
02
Aborted
Command
-
End-to-End
Application Tag Check
0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0
B
10
03
Aborted
Command
-
End-to-End
Reference Tag Check
0 1 0 1 0 0 0 1 0 0 0 1 0 0 0 0
B
11
03
Aborted Command - OCT Timeout In
Recovery
B
26
00
Write/Erase/Read Parameter Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
B
2E
00
Write/Erase/Read Parameter Retry Error
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
B
2E
02
SCT Read or Write Timeout
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
0 1 0 1 0 0 0 1 0 0 0 0 0 1 0 0
B
3F
0F
Aborted
Command
-
Echo
Buffer
Overwritten
B
44
00
Internal Target Failure
0 1 v 1 0 0 0 1 v v 0 v 0 v 0 0
B
47
01
Data Phase CRC Error
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0
B
4B
00
Data Phase Error
0 1 0 1 0 0 0 1 1 0 0 0 0 1 0 0
356
Hard Disk Drive Specification