Текст страницы
Symbol Conventions
The symbols that may be found in this document are defined as follows.
▷Rack Mounting
②Install Your Switch
Symbol
Description
Provides additional information to emphasize or supplement important
points of the maintext.
Please select an appropriate installation method according to the
actual needs. The following figures are for reference only.
Steps
1. Check the grounding and stability of the rack.
2. Use M3 screws provided in the package to fix the two L-shaped
Indicates a potentially hazardous situation, which if not avoided, could
result in equipment damage, data loss, performance degradation, or
unexpected results.
Before You Start
brackets to both sides of the device.
Indicates a hazard with a high level of risk, which if not avoided, will
result in deathor serious injury.
①Learn About Your Switch
▷Front Panel (Example)
• Ensure that the desktop, wall, or rack is stable and firm
enough.
• Keep the room well-ventilated. Leave at least 10 cm heat
dissipation space around the device.
• Keep at least 1.5 cm vertical distance between two adjacent
devices for rack mounting.
PoE Indicator
▷Desktop Placement
Gigabit PoE RJ45 Port
LINK/ACT Indicator
Gigabit SFP Fiber Optical Port Indicator
(Port 18)
Gigabit RJ45 Port Indicator
(Port 17)
Place the device on the desk.
▷Wall Mounting
The number of screws provided for fixing L-shaped brackets
to the device varies with device models.
PoE-MAX Indicator
Steps
1. Check the distance between the two hanging holes at the
3. Fix two self-prepared M5 or M6 nuts to the rear side of the
Reset Button
PWR Indicator
Smart Managed Switch
rack on both sides respectively.
Gigabit RJ45 Port
(Port 17)
Gigabit SFP Fiber Optical Port
(Port 18)
▷Rear Panel (Example)
bottom of the device.
2. Insert two self-prepared M4 screws into the wall.
3. Align the hanging holes with screws, and hang the device on
Grounding Terminal
Power Supply
the screws.
Quick Start Guide
• Device appearances vary with models.
The figures above are for your reference
only. The actual device prevails.
• Scan the QR code to obtain product
introduction,
packing
list,
and
appearance of the desired device model.
• The load-bearing capacity of the wall should be three times
more than the weight of the device.
• Ensure that the distance between the two screws equals to
the distance between the two hanging holes.
• Set aside at least 4 mm of the screw bodies outside the wall.
About this Document
●This Document includes instructions for using and managing the Product. Pictures, charts,
images and all other information hereinafter are for description and explanation only.
●The information contained in the Document is subject to change, without notice, due
to firmware updates or other reasons. Please find the latest version of the Document
at the Hikvision website (https://www.hikvision.com). Unless otherwise agreed, Hangzhou
Hikvision Digital Technology Co., Ltd. or its affiliates (hereinafter referred to as "Hikvision")
makes no warranties, express or implied.
●Please use the Document with the guidance and assistance of professionals trained in
supporting the Product.
About this Product
This product can only enjoy the after-sales service support in the country or region where the
purchase is made.
Acknowledgment of Intellectual Property Rights
●Hikvision owns the copyrights and/or patents related to the technology embodied in the
Products described in this Document, which may include licenses obtained from third
parties.
●Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No
part of this Document may be excerpted, copied, translated, or modified in whole or in part
by any means without written permission.
●
and other Hikvision’s trademarks and logos are the properties of Hikvision in
various jurisdictions.
●Other trademarks and logos mentioned are the properties of their respective owners.
LEGAL DISCLAIMER
●TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED
"AS IS" AND "WITH ALL FAULTS AND ERRORS". HIKVISION MAKES NO WARRANTIES,
EXPRESS
OR
IMPLIED,
INCLUDING
WITHOUT
LIMITATION,
MERCHANTABILITY,
SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE
PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION,
OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER
BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY,
OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
●YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT
SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL
OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK,
HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
●YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND
YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE
APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A
MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING
WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS
OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR
BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR
EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
●IN THE EVENT OF ANY CONFLICTS BETWEEN THIS DOCUMENT AND THE APPLICABLE LAW,
THE LATTER PREVAILS.
© Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
2
3
1
4
▷With Grounding Bar
④Connect Your Switch to a Peer Device
⑤Power Your Switch On
4. Place the switch against the rack so that the holes on the
Grounding Terminal
Please use the attached power cord (and power adapter, if any)
in package to power on the device.
Before powering your switch on, make sure that:
▷RJ45 Port
Use a network cable to connect the device to the RJ45 port of a
peer device such as the IP camera (IPC), NVR, switch, etc.
L-shaped brackets are aligned with the holes where the nuts
have been fixed.
5. Fix the brackets to the front side of the rack with two self-
Grounding Cable
Grounding Bar
prepared M5 or M6 screws on both sides respectively to stably
install your device.
• The operating power supply is compliant with the rated input
standard.
• Port cables and grounding cables are correctly connected.
• If there is outdoor cabling, connect a lightning rod and
lightening arrester to the cable.
Steps
1. Connect one end of the grounding cable to the binding post
on the grounding bar.
2. Connect the other end of the grounding cable to the device's
grounding terminal and fix the screw.
Power cables and network cables cannot be wired together,
otherwise the PD or switch ports will be burnt.
▷SFP Fiber Optical Port
If the device has a fiber optical port or a combo, connect the
device to a peer device through an optical fiber connecting
optical modules plugged into fiber optical ports respectively.
• When connected to a network cable, the combo is a RJ45 port.
• When plugged into with an optical module and connected to
an optical fiber, the combo functions as a fiber optical port.
• When connected to both the network cable and optical fiber at
the same time, the combo works as a fiber optical port.
▷Without Grounding Bar
⑥Manage Your Switch on Hik-Partner Pro
Steps
1. Connect the two paired SFP optical modules with an optical
Grounding Terminal
fiber.
2. Hold theSFP opticalmodule from oneside, andsmoothly plug
You can batch activate Hikvision devices such as switches, NVRs,
and IPCs, and add the devices to a site for device management on
the Hik-Partner Pro app.
Grounding Cable
it into the switch along with the SFP port slot until the optical
module and the switch are closely attached.
3. After powering your switch on, check the status of the
Earth
Angle Steel
LINK/ACT indicator.
– If the indicator is lit, the link is connected.
– If the indicator is unlit, the link is disconnected. Check the
≥0.5 m
line, and make sure the peer device has been started.
③Ground Your Switch
Before You Start
• Install the Hik-Partner Pro app.
• Power on the devices and connect them to the network.
• Connect your phone to a Wi-Fi network. If you cannot connect
to a Wi-Fi network, use a USB-C RJ45 adapter to connect your
phone to a LAN.
• Make sure your phone and the devices in your networking
(such as the switch, NVR, and IPCs) are on the same LAN and
are not activated.
Steps
1. Bury an angle steel or steel pipe (≥0.5 m) into the mud land.
2. Weld one end of the grounding cable to the angle steel or
Grounding is used to quickly release overvoltage and overcurrent
induced by lightening for the switch, and to protect personal
safety. Select an appropriate grounding method according to
your needs.
steel pipe and embalm the welding point via electroplating or
coating.
3. Connect the other end of the grounding cable to the device's
• Single-mode optical modules need to be paired.
• Do not bend an optical fiber (curvature radius ≥10 cm)
overly.
• Do not look directly at an optical fiber connector as laser
is harmful to eyes.
The following network topology is for your reference only. You
can connect your devices according to your actual networking
requirements.
grounding terminal.
UD33606B-C
5
6
7
8