Текст страницы
Installing or removing
Disposing of dust
CAUTION: Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
CAUTION: Be sure to wear dust mask when
disposing of dust.
NOTICE: Before installing the dust collection
system, clean the joint parts of the tool and the
dust collection system. Foreign matters on the joint
parts may cause it difficult to install the dust collection
system. If any dust remains on the air duct, the dust
comes into the tool and causes jam in the airflow or
breakage of the tool.
CAUTION: Be sure that the tool is completely
stopped when disposing of dust.
CAUTION: Empty the dust case regularly before
the dust case becomes full. Failure to do so may decrease
the dust collection performance and cause dust inhalation.
To install the dust collection system, insert the tool
completely into the dust collection system until the tool
is locked in place with a little click.
► Fig.26
To remove the dust collection system, pull up the tool
while pressing the lock-off button.
► Fig.27: 1. Lock-off button
CAUTION: The performance of dust collection
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide. Failure to do so may cause dust inhalation.
Adjusting nozzle position
1.
Remove the dust case while pressing down the
lever of the dust case.
► Fig.31: 1. Lever
CAUTION: Do not point the nozzle at yourself
or others when releasing the nozzle by pushing
the guide adjustment button.
2.
Open the cover of the dust case.
► Fig.32: 1. Cover
3.
Dispose of the dust, and then clean the filter.
► Fig.33
Slide in and out the nozzle guide while pressing the
guide adjustment button, and then release the button
at an exact position where the tip of the drill bit sits just
behind the front surface of the nozzle.
► Fig.28: 1. Nozzle guide 2. Guide adjustment button
3. Tip of drill bit 4. Front surface of nozzle
Adjusting drilling depths
NOTICE: When cleaning the filter, tap the case
of the filter gently by hand to remove dust. Do not
tap the filter directly; touch the filter with brush
or similar; or blow compressed air on the filter.
Doing so may damage the filter.
Replacing filter of dust case
1.
Remove the dust case while pressing down the
lever of the dust case.
► Fig.34: 1. Lever
Drilling depths can be adjusted by changing the lengths
between the depth adjustment button and the support
arm for nozzle guide. Press and hold the depth adjust-
ment button and slide it to your desired position.
► Fig.29: 1. Depth adjustment button 2. Nozzle guide
3. Support arm for nozzle guide 4. Drilling
depths
2.
Open the filter cover of the dust case.
► Fig.35: 1. Filter cover
Beating dust on the filter
3.
Remove the filter from the filter case.
► Fig.36: 1. Filter 2. Filter case
4.
Attach a new filter to the filter case, and then
attach the filter cover.
CAUTION: Do not turn the dial on the dust
case while the dust case is removed from the
dust collection system. Doing so may cause dust
inhalation.
5.
Close the cover of the dust case, and then attach
the dust case to the dust collection system.
Replacing sealing cap
CAUTION: Always switch off the tool when
turning the dial on the dust case. Turning the dial
while the tool is running may result in the loss of
control of the tool.
By beating the dust on the filter inside the dust case,
you can keep the vacuum efficiency and also reduce
the number of times to dispose of the dust.
Turn the dial on the dust case three times after col-
lecting every 50,000 mm
3 of dust or when you feel the
vacuum performance declined.
1.
Insert a flat-blade screwdriver into one of the grooves
placed on the sides of the nozzle head. Tilt the flat-blade
screwdriver at an angle to squeeze and pop the cube hook of
the sealing cap out. Then peel the rubber edge of the sealing
cap away from the rim of the nozzle head opening.
► Fig.37: 1. Sealing cap 2. Cube hook 3. Groove
4. Nozzle head
NOTE: 50,000 mm
3 of dust equivalents to drilling 10
holes of ø10 mm and 65 mm depth.
► Fig.30: 1. Dust case 2. Dial
2.
Set one of cube hooks of a new sealing cap into
the lower part of the groove in the nozzle head with a
recessed surface of the sealing cap facing forward.
► Fig.38: 1. Cube hooks 2. Lower part of the groove
3. Sealing cap 4. Recessed surface
15
ENGLISH