Текст страницы
22-1. Screws
23-1. Screws
24-1. Guard cover
25-1. Connector
26-1. Change lever
26-2. Screw
26-3. Crank cap cover
27-1. Control plate
28-1. Screws
28-2. Crank cap
29-1. Hammer grease
30-1. Connector
11-1. Side grip
12-1. Bit shank
12-2. Bit grease
13-1. Bit
13-2. Release cover
14-1. Bit
14-2. Release cover
15-1. Change lever
15-2. Pointer
16-1. Change lever
16-2. Pointer
17-1. Depth gauge
17-2. Lock button
20-1. Blow-out bulb
ENGLISH (Original instructions)
Explanation of general view
1-1. Switch trigger
2-1. Switch button
3-1. Adjusting dial
4-1. Change lever
4-2. Pointer
5-1. Change lever
5-2. Pointer
6-1. Change lever
6-2. Pointer
7-1. Switch button
8-1. Power-ON indicator lamp (green)
8-2. Service indicator lamp (red)
10-1. Side handle
10-2. Clamp nut
SPECIFICATIONS
Model
HR4003C
HR4013C
HR5202C
HR5212C
Carbide-tipped bit
40 mm
52 mm
Capacities
Core bit
105 mm
160 mm
No load speed (min-1)
250 - 500
150 - 310
Blows per minute
1,450 - 2,900
1,100 - 2,250
Overall length
479 mm
599 mm
Net weight
6.2 kg
6.8 kg
10.9 kg
11.9 kg
Safety class
/II
• Due to our continuing program of research and development, the specifications herein are subject to change without notice.
• Specifications may differ from country to country.
Model HR5212C
Sound pressure level (LpA) : 98 dB (A)
Sound power level (LWA) : 109 dB (A)
Uncertainty (K) : 3 dB (A)
Wear ear protection
ENG900-1
Vibration
The
vibration
total
value
(tri-axial
vector
sum)
determined according to EN60745:
Model HR4003C
Work mode : chiselling function with side handle
Vibration emission (ah,CHeq) : 9.0 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode : chiselling function with side grip
Vibration emission (ah,CHeq) : 9.0 m/s2
Uncertainty (K) : 1.5 m/s2
Work mode : hammer drilling into concrete
Vibration emission (ah,HD) : 10.0 m/s2
Uncertainty (K) : 1.5 m/s2
• Weight according to EPTA-Procedure 01/2003
ENE044-1
Intended use
The tool is intended for hammer drilling in brick,
concrete and stone as well as for chiselling work.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
ENG905-1
Noise
The
typical
A-weighted
noise
level
determined
according to EN60745:
Model HR4003C, HR4013C
Sound pressure level (LpA) : 92 dB (A)
Sound power level (LWA) : 103 dB (A)
Uncertainty (K) : 3 dB (A)
Model HR5202C
Sound pressure level (LpA) : 99 dB (A)
Sound power level (LWA) : 110 dB (A)
Uncertainty (K) : 3 dB (A)
4