Текст страницы
charge the rechargeable battery at least once every
4 to 6 weeks.
• Life of the rechargeable battery: Even when switched
off, the rechargeable battery discharges continuously.
If the appliance is out of use for a longer period of time,
Troubleshooting
Problem
Possible Cause
Remedy
The appliance is without function.
The rechargeable battery is
empty.
Charge the rechargeable battery.
The rechargeable battery is
defect.
Contact our service or your dealer.
The rechargeable battery is
empty.
Charge the rechargeable battery.
During operation, the LED on
the switch flashes for approx.
30 seconds. The appliance then
switches off.
Weak suction power.
The battery is almost empty.
Charge the rechargeable battery.
The dust container is full.
Empty the dust container.
The filters are dirty.
Clean the filters as described under “Maintenance”.
CAUTION:
Only resume operation with dry filters!
The battery rechargeable does
not hold a charge.
The rechargeable battery has
reached the end of its life.
Contact our service or your dealer.
Technical Data
Information about
the power supply used
Value
Unit
Model identifier
SEU007A-140050
Input voltage
100 – 240
V~
Input alternating current frequency
50 – 60
Hz
Model:...............................................................PC-AKS 3102
Net weight (Handheld unit,
charging station, power supply unit):..............approx. 0.83 kg
Protection class (appliance):...............................................
Protection class (power supply unit):...................................
Output voltage AC / DC
14.0
V DC
Output current
0.5
A
Rechargeable Battery:.................3 × 3.7 V, 2000 mAh Li-Ion
Operating time:.....................................30 minutes maximum
Charging time:.............................................approx. 4.5 hours
Output power
7.0
W
Average efficiency in operation
79.9
%
Low load efficiency (10 %)
*
%
The right to make technical and design modifications in
the course of continuous product development remains
reserved.
No-load power consumption
0.06
W
* not applicable due to an output power of less than 10 W.
This appliance has been tested according to all applicable,
current CE directives and built according to the latest safety
regulations.
The relevant load conditions are as follows:
Percentage of nameplate output current
Load condition 1
100 % ± 2 %
Product Specifications in Accordance with
Regulation (EU) 2019 / 1782 Power Supplies
Load condition 2
75 % ± 2 %
Load condition 3
50 % ± 2 %
Information about
the power supply used
Value
Unit
Load condition 4
25 % ± 2 %
Load condition 5
10 % ± 1 %
Load condition 6
0 % (no-load condition)
Clatronic International GmbH
Commercial register number
HRB 9158
Industriering Ost 40,
47906 Kempen
Germany
12