Текст страницы
Airflow range setting
■ Take the air-conditioner location into account and adjust the left/right airflow range to maximize air-conditioning.
If the air-conditioner is running, press the ON/OFF
button to stop.
1
Press the AIRFLOW U/D (UP/DOWN) button and the
AIRFLOW L/R (LEFT/RIGHT) button together for
5 seconds or more.
The airflow range setting cannot be made while the unit is running. 2
Setting the airflow range.
The airflow range setting display illuminates. 3
Press the AIRFLOW L/R (LEFT/RIGHT) button and adjust to the desired
location.
Each time the AIRFLOW L/R (LEFT/RIGHT) button is pressed, the display is
switched in the order of:
(Center Installation)
(Right End Installation)
(Left End Installation)
Press the ON/OFF button.
4
The air-conditioner’s airflow range is set.
Press within 60 seconds of setting the airflow range (while the airflow range
setting display illuminates).
Air-conditioner installation location and airflow range
The diagram below indicates the airflow ranges corresponding to the air-conditioner’s installation location. Consider your room’s layout
and set the airflow range to maximize air-conditioning.
Airflow range
Airflow range
Airflow range
(Left End Installation)
(Center Installation)
(Right End Installation)
NOTE
x Once the airflow range setting is configured, it is stored in the air-conditioner even if the power source is turned off. To change the
airflow range setting, set range again with the remote control.
x During the operation, an airflow range setting cannot be set.
x When the air-conditioner is installed at the location within 50 cm from the wall, it is recommended to change the airflow range setting
to “Right End Installation” or “Left End Installation”.
EN-12