Текст страницы
ENGLISH (Original instructions)
SPECIFICATIONS
Model:
M9506
M9507
M9508
Wheel diameter
100 mm
115 mm
125 mm
Max. wheel thickness
4 mm
6.4 mm
Spindle thread
M10 x 1.5
M14 x 2
Rated speed (n)/ No load speed (n0)
11,000 min
-1
Overall length
261 mm
Net weight
1.6 kg
1.9 kg
Safety class
/II
•
Due to our continuing program of research and development, the specifications herein are subject to change
without notice.
•
Specifications may differ from country to country.
•
Weight according to EPTA-Procedure 01/2003
Symbols
Noise
The followings show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read instruction manual.
Wear safety glasses.
DOUBLE INSULATION
The typical A-weighted noise level determined accord-
ing to EN60745:
Model M9506
Sound pressure level (LpA) : 86 dB(A)
Sound power level (LWA) : 97 dB (A)
Uncertainty (K) : 3 dB(A)
Model M9507
Sound pressure level (LpA) : 88 dB(A)
Sound power level (LWA) : 99 dB (A)
Uncertainty (K) : 3 dB(A)
Model M9508
Sound pressure level (LpA) : 88 dB(A)
Sound power level (LWA) : 99 dB (A)
Uncertainty (K) : 3 dB(A)
WARNING: Wear ear protection.
Vibration
Only for EU countries
Do not dispose of electric equipment
together with household waste material! In
observance of the European Directive, on
Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
The vibration total value (tri-axial vector sum) deter-
mined according to EN60745:
Model M9506
Work mode: surface grinding
Vibration emission (ah, AG) : 6.5 m/s
2
Intended use
Uncertainty (K) : 1.5 m/s
2
The tool is intended for grinding of metal and stone
materials without the use of water.
Model M9507
Work mode: surface grinding
Vibration emission (ah, AG) : 7.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
Power supply
Model M9508
Work mode: surface grinding
Vibration emission (ah, AG) : 7.0 m/s
2
Uncertainty (K) : 1.5 m/s
2
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
NOTE: The declared vibration total value(s) has been
measured in accordance with a standard test method
and may be used for comparing one tool with another.
NOTE: The declared vibration total value(s) may also
be used in a preliminary assessment of exposure.
3
ENGLISH