Текст страницы
Main technical specifications
EN
Cold water supply pressure, min/max
0.05 / 0.7 MPa
Single-phase power supply network, voltage, frequency
230 V~, 50 Hz
Tubular heater capacity
2000 W
Diameter of the threads of the cold and hot water nipples
G1/2
International Protection Marking
IPX4
Operation at ambient temperature
+3...+40°С
Adjustment range of water heating temperature
+18…+74°С
±5°С
Accuracy of temperature maintenance in storage mode
Daily constant loss,
Actual annual electricity consumption*,
Volume,
Average heating time
(kW/24 h)
0
at ∆Т=45 С
(l)
(kW/h)
(* for daily constant loss)
(2 kW)
0,56
204,4
10
16 min
0,69
251,8
15
28 min
The manufacturer reserves the right to change the design and characteristics of the water heater
without prior notice.
Information on the place of application and the method of determining the date of
manufacture:
The release date of the product is encoded in a unique serial number located on the nameplate (label)
at the bottom of the product case. The serial number of the product consists of thirteen digits. The third
and fourth digit of the serial number is the year of manufacture, the fifth, sixth is the month of
manufacture, the seventh, and eighth is the day of the manufacture of the EWH.
Safety precautions
1. All installation, plumbing and electrical work must be carried out by qualified personnel
only!
2. Electrical safety and anti-corrosion protection of the EWH are guaranteed only if there is an
effective grounding performed in accordance with the current Electrical Installation Code (EIC).
3. When installing and operating the EWH, the following is prohibited:
to connect the power supply if the EWH is not filled with water;
џ
to remove the cover when the power is on;
џ
to use the EWH without grounding or use water pipes for grounding;
џ
to connect the EWH to water supply system with a pressure of more than 0.7 MPa. If the pressure in
џ
the water main exceeds 0.7 MPa, or is not stable and periodically exceeds 0.7 MPa, then at the inlet
14