3. STARTING AND OPERATION
3.1. Commissioning
3.1.1. Shut off the hot water supply of the central water supply system. Before connect the appliance to power source,
fill the tank up with mains water. To do this, turn on hot water mixer tap and then tap of cold water supplied to the water heater.
3.1.2. Once the water heater is full, the water will flow from the mixer tap. Check the flange for leakages. Center it and tighten
the nuts if necessary.
3.1.3. Turn the hot water tap on the mixer off.
3.1.4. Connect the appliance to power source.
3.2. Temperature control
3.2.1. In models equipped with external control, water temperature can be controlled by a handle connected to the thermostat
in accordance with marks.
3.2.2. The temperature is set by using the regulation button clockwise to increase the temperature of heating and counterclockwise
to decrease it.
3.2.3. The indicator lamp is constantly lighting during heating phase, and turns off after reaching the set temperature.
3.2.4. If an appliance model does not have an external control, temperature can be set by turning the adjusting screw of the
thermostat in the range marked by «+» and «-» signs. To do so, disconnect the water heater from the power supply and remove
the plastic cover of the appliance.
3.2.5. It is recommended to install the controller in a position corresponding approximately to 75% of the maximal value. In
this case, the appliance is operated in economy mode significantly reducing the rate of scale formation.
4. MAINTENANCE AND REPAIR WORKS
Attention! Do not try to repair the appliance by yourself. All maintenance and repair works should be carried
out by a qualified technician in conformity with the safety norms and with any provisions set forth in this manual.
4.1. Water Drain
If there is a possibility that the ambient temperature drops below 0°C in the room where the appliance is installed, drain
water from the water heater.
4.1.1. Disconnect the appliance from the electrical supply;
4.1.2. Make sure that the water in the appliance is of safe temperature;
4.1.3. Turn off the tap of cold water supply to the water heater;
4.1.4. Turn on the hot water tap on mixer for pressure relief inside the tank;
4.1.5. Turn on the T-connector stop valve installed at hot water outlet (marked with red ring) for air access into the tank. If it is
absent, remove the connections at the water heater outlet;
4.1.6. Connect drain hose directed into the sewer to the T-connector stop valve installed at the cold water inlet of the water
heater (marked with the blue ring) and open it. If there is no T-connector, connect the hose to water heater inlet;
4.1.7. After draining, make sure there is no water inside the water heater.
Freezing of water inside the water heater leads to irreversible changes and defects.
It invalidates all warranty liability on the part of the manufacturer.
4.2. Replacing internal parts
Prior to work, disconnect the appliance from the power supply and drain the water from the water heater.
Remove the appliance cover.
To replace the thermostat pull it straight out ot the cluster and disconnect from power supply.
To replace heating element and magnesium anode (models with an autoclave flange) remove the nut (D in Fig. 3), remove the
flange holder (S in Fig. 3) and open the flange (F in Fig. 3) by pressing it inside. Remove the flange by turning it on its axis.
To replace heating element and magnesium anode (models with a flange on the 5 bolts) remove 5 nuts (C in Fig. 4) and remove
the flange (F in Fig. 4).
During reassembly, make sure that all components are put back in their original positions.
We recommend replacing the flange gasket every time when reassembling.
Prior to any repair or maintenance procedure, disconnect the unit from power source.
Use original spare parts of the manufacturer only.
4.3. Periodical maintenance
4.3.1. Magnesium anode
The magnesium anode rod is an integral part of the protection system of water tank and heating element against
corrosion against corrosion.
It’s necessary to check the condition of the magnesium anode rod ANNUALLY.
In case of severe wear, the magnesium anode rod must be replaced.
The warranty for water tank and heating element with the worn with the worn magnesium anode rod (residual
volume is less than 30%) is not valid.
The magnesium anode rod should be replaced at least once in 24 months (except for the water
heater with the internal tank made of stainless steel).
The magnesium anode rod is a consumable item that cannot be replaced underwarranty.
4.3.2. Safety valve
The safety valve (pressure safety device) must be inspected regularly to check that it is not blocked or
damaged. Replace the valve or remove limescale deposits if necessary. If the safety valve is equipped
with a lever, regular valve correct operation check procedure can be performed with its help.
The drainage pipe of the safety valve may generate water droplets. It is not a defect; it is due to relief work
function of the valve pressure relief that occurs when water is heated in enclosed space of the inner tank.

37

Бытовая техника / Техника для дома / Водонагреватели и котлы отопления / Водонагреватели электрические

ARISTON PRO1 ECO INOX ABS PW 50 V

68 стр.
Бытовая техника / Техника для дома / Водонагреватели и котлы отопления / Водонагреватели электрические

ARISTON PRO1 ECO INOX ABS PW 50 V

68 стр.
Бытовая техника / Техника для дома / Водонагреватели и котлы отопления / Водонагреватели электрические

ARISTON PRO1 R INOX ABS 100

68 стр.
Бытовая техника / Техника для дома / Водонагреватели и котлы отопления / Водонагреватели электрические

ARISTON PRO1 R INOX ABS 100

68 стр.
Бытовая техника / Техника для дома / Водонагреватели и котлы отопления / Водонагреватели электрические

Aceline D30-15F2, D50-15F2, D80-15F2, D100-15F2

20 стр.