Текст страницы
correctly. If these do not identify/remedy the problem, contact your service agent. WARNING: Switch off and
remove plug from power source before investigating fault.
Symptom
Possible Cause
Remedy
Chain saw fails to
operate
Out of battery.
Fuse faulty.
Charge the battery pack.
Replace fuse.
Over heating
Chain saw
operates
intermittently
Applying too much pressure while
cutting.
Loose connection.
Internal wiring defective.
On/Off switch defective.
Place the machine in a cool, ventilated
place to cool it down.
Applying relatively less pressure while
cutting.
Contact service agent.
Contact service agent.
Contact service agent.
Dry chain
No oil in reservoir
Vent in oil filler cap clogged
Oil passage clogged
Refill oil
Clean cap
Clean oil passage outlet
Chain/chain bar
over-heats
No oil in reservoir
Vent in oil filler cap clogged
Oil passage clogged
Chain is over tensioned
Dull chain
Refill oil
Clean cap
Clean oil passage outlet
Adjust chain tension
Sharpen chain or replace
Chain saw rips,
vibrates, does not
saw properly
Chain tension too loose
Dull chain
Chain worn out
Chain teeth are facing in the wrong
direction
Adjust chain tension
Sharpen chain or replace
Replace chain
Reassemble with chain in correct
direction
23
- Measured Sound Power Level 94.7 dB(A)
- Declared Guaranteed Sound Power Level 96 dB(A)
DECLARATION OF
CONFORMITY
WG323E WG323E.9
2000/14/EC amended by 2005/88/EC:
- Conformity Assessment Procedure as per Annex V
- Measured Sound Power Level 95.2 dB(A)
- Declared Guaranteed Sound Power Level 96 dB(A)
Standards conform to
EN 60745-1
EN 60745-2-13
EN ISO 3744
EN 55014-1
EN 55014-2
Parts of EN ISO11680-1
We,
Positec Germany GmbH
Grüner Weg 10, 50825 Cologne, Germany
Declare that the product
Description Battery-powered chain saw and pole
saw
Type WG322E WG322E.9 WG323E WG323E.9
(3 - designation of machinery, representative of
chain saw and pole saw)
Function Cutting wood
The person authorized to compile the technical file,
Name Marcel Filz
Address Positec Power Tools (Europe)Ltd,
PO Box 6242, Newbury, RG14 9LT, UK
Complies with the following Directives:
2006/42/EC
2014/30/EU
2011/65/EU
2000/14/EC amended by 2005/88/EC
The notified body involved
Name: Intertek Deutschland GmbH (Notified
body 0905)
Address: Stangenstraße 1, 70771 LEINFELDEN-
ECHTERDINGEN
Certification No.: 17SHW1086-01 (WG322E
WG322E.9) 17SHW1166-01 (WG323E
WG323E.9)
Suzhou 2018/03/09
Allen Ding
Deputy Chief Engineer, Testing & Certification
Positec Technology (China) Co., Ltd.
18, Dongwang Road, Suzhou Industrial
Park, Jiangsu 215123, P. R. China
WG322E WG322E.9
2000/14/EC amended by 2005/88/EC:
- Conformity Assessment Procedure as per Annex V