Текст страницы
3 Installation
• The product must be connected
Rooms that do not have openable doors and/or windows
that open directly to the outer environment
to the mains supply only by an
author- ised and qualified person.
The product’s warranty period
starts only after correct installa
tion. Manufacturer shall not be
held responsible for damages aris
ing from procedures carried out by
unauthorised persons.
A
• The power cable must not be
If the room where the appliance is installed does
not have a door and/or a window that opens direct
ly to the outer environment, other products shall be
sought that definitely provide a fixed nonadjusta
ble and non-closable ventilation opening which
meets the total minimum ventilation opening re
quirements for the total gas consumption of the
appliance as indicated in the above table.Also the
appropriate building regulations advise should be
followed. Where a room or internal space contains
more than one gas appliance, additional ventilation
area shall be provided on top of the requirement
given in the table above. Size of additional venti
lation area shall be appropriate to regulations of
other gas appliances.
clamped, bent or trapped or come
into contact with hot parts of the
product. A damaged power cable
must be replaced by a qualified
electrician. Otherwise, there is risk
of electric shock, short circuit or
fire!
• Connection must comply with national regula
tions.
• The mains supply data must correspond to the
data specified on the type label of the product.
Type label is at the rear housing of the product.
There should also be a minimum clearance of
10mm on the bottom edge of the door that opens
to the inner environment in the room where the
appliance is installed.You must ensure that items
such as carpets and other floorcoverings etc., do
not affect the clearance when the door is closed.
• Power cable of your product must comply with
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room con
taining a bath or a shower.
The cooker must not be installed in a bed- siting
room of less than 20m³.
Before starting any work on the elec
trical installation, disconnect the
product from the mains supply.
the values in “Technical specifications” table. A
There is the risk of electric shock!
Do not install this appliance in a room below
ground level unless it is open to ground level on at
least one side.
• Power cable plug must be within
3.2 Installation and connection
easy reach after installation (do
not route it above the hob).
• The product must be installed in accordance
• While performing the wiring, you
with all local gas and electrical regulations.
Electrical connection
C
Connect the product to a grounded outlet/line pro
tected by a miniature circuit breaker of suitable
capacity as stated in the “Technical specifications”
table. Have the grounding installation made by a
qualified electrician while using the product with or
without a transformer. Our company shall not be
liable for any damages that will arise due to using
the product without a grounding installation in ac
cordance with the local regulations.
must apply with the national/local
electrical regulations and must
use the appropriate socket out
let/line and plug for oven. In case
of the product’s power limits are
out of current carrying capabil
ity of plug and socket outlet/line,
the product must be connected
through fixed electrical installation
directly without using plug and
socket outlet/line.
Plug the power cable into the socket.
Built-in Hob / User Manual