Текст страницы
Troubleshooting
Technical specifications
Appliance is not running
Battery pack and quick charger in scope of delivery of:
WD 3 Battery Set
WD 3 Battery Premium Set
(Battery pack Battery Power 36/25 / standard charger
Battery Power BC 36 V)
Device
Rated power
W
300
Illustration
The battery pack is not seated correctly in the bat-
tery holder, insert the battery pack into the battery
holder and let it click into place.
Charging state of the battery pack (see display) too
low, charge the battery if necessary.
Defect battery pack or charger, replace battery
pack or charger with new accessory.
Operating time when battery fully
charged (max.)
min
15
The device switches off automatically
Protective class
III
Type of protection
IPX4
Battery pack Battery Power 36/25
Nominal voltage
V
36
Device/battery pack is overheated, wait briefly to
allow device/battery pack to cool down.
Container is full of water, which activated the float
tank and empties the container.
Decreasing cleaning power
Rated capacity
(according to IEC/EN 61690)
Ah
2,4
Ah
2,5
Rated capacity
(according to specifications of cell
manufacturer)
Nominal width
(in accordance with UN 3480)
Wh
86,4
Max. charging current
A
4
Battery type
Li-Ion
Accessories, suction hose or suction pipes are
clogged.
Remove the clog with a suitable aid.
Illustration
Filter bag is full, install new filter bag.
Figure
-
Cartridge filter is dirty, knock off dirt from cartridge
filter and clean under running water if necessary.
Replace damaged cartridge filter.
Recommendation: Replace cartridge filter 1x per year.
Weight
kg
0,9
Dimensions (l x b x h)
mm
133x88x72
Standard charger Battery Power BC 36 V
Battery pack nominal voltage
V
36
Max. charging current
A
0,5
Battery type
Li-Ion
Mains voltage
V
100-240
Frequency
Hz
50-60
Power input (max.)
A
0,3
Protective class
II
Weight (without battery pack)
g
205
Subject to technical modifications!
– 13
22
EN