HUMIDIFICATION SETTING
Always be sure to remove the
power plug from the wall outlet.
PREPARATION
PLASMACLUSTER ION SPOT MODE
REFILLING THE WATER TANK
FILTER INSTALLATION
Use this mode when you want to remove adhering odor,
germs, and other substances from cloths, sofas and curtains.
2
1
Remove the Back Panel.
Remove
the Water Tank.
1
3
Install the filters in the correct order as
shown.
1
HEPA Filter
Adjust Front Louver manually.
Tag
NOTE
2
Back Panel
Fill the Water Tank
with the tap water.
Deodorizing Filter
Install the Back Panel.
• Emits highdensity Plasmacluster Ions only in the forward
direction.
• Discharges stronger air for 8 hours. When the operation
finishes, the unit will return to its prior operation mode.
• The Plasmacluster Ion can not be turned “OFF”. (Ref.E-10)
2
4
Remove the plastic bag
from the each filter.
HEPA Filter
Deodorizing Filter
Click
SELECTING MODE
3
ENGLISH
2
To prevent leaks ,
securely tighten the
Tank Cap.
1
3
3
Click
4
Install
the Water Tank.
2
NOTE
• When replacing the filter, making a memo of the start of
use date is recommended.
SLEEP
POLLEN
MAX
MED
LOW
1
NOTE
OPERATION
START/STOP
INTELLIGENT MODE (KC-G61R / KC-G51R)
ON OFF
START STOP
The fan speed is automatically controlled depending on the 7
detection. (Ref.E-1)
SLEEP
The unit will operate quietly, and the fan speed is
automatically switched depending on the amount of impurities
in the air.
The Front Display, Cleanliness Monitor and Air Outlet LED
go off automatically.
(When light control is set to "Auto". Ref.E-11)
POLLEN
The DUST SENSOR sensitivity is automatically set to “HIGH”
and quickly detects impurities such as dust and pollen and
clean the air powerfully.
NOTE
CLEAN ION SHOWER MODE AUTO MODE (KC-G41R)
CHILD LOCK
Operation of the operation panel will be locked.
When operating with Humidification ON in the modes in
the table below, the unit automatically controls humidity by
sensing temperature and humidity. (Except MAX / MED /
LOW mode.)
The fan speed is automatically controlled depending on the
5 detection. (PM2.5 / Usual dust / Temperature /Humidity /
Light)
ON CANCELLATION
The unit releases Plasmacluster ions with strong airflow
and collects dusts while decreasing static electricity for
10 minutes. After that, the DUST sensor sensitivity is
automatically set to ”HIGH”and quickly detects impurities
and clean the air powerfully for 50 minutes.
Humidity
Temperature
SLEEP
NOTE
ALL MODE
(Except MAX / MED / LOW / SLEEP)
MODE
~18 ºC
65 %
65 %
18 ºC~24 ºC
60 %
65 %
• When the operation finishes after
60 minutes, the unit will return
to the prior operation mode. It is
NOTE
24 ºC~
55 %
60 %
• Front Display, Cleanliness Monitor and Air Outlet LED
automatically switch ON and OFF based on room
brightness. (When light control is set to "Auto". Ref.E-11)
able to change the other mode
during this mode.
• The Plasmacluster Ion can not
be turned “OFF”. (Ref.E-10)
more
3 sec.
more
3 sec.
E-7
E-8