Инструкция климатический комплекс Sharp KIN41RW

SPECIFICATIONS (стр. 66 из 68)

Бренд: Sharp

Страница 66 документа Климатический комплекс Sharp KIN41RW. Раздел: Климатические комплексы. Бренд: Sharp.

Текст страницы

SPECIFICATIONS

Model
KI-N51R
KI-N41R

Power supply
220 - 240 V ~ 50 - 60 Hz

Fan Speed Adjustment
MAX
MED
LOW
MAX
MED
LOW

Fan Speed (m3 / hour)
306
168
60
240
150
60

Rated Power (W)
51
17
5.5
29
14
5.5

CLEAN AIR

Noise Level (dBA) *1
51
40
17
46
38
17

Fan Speed (m3 / hour)
252
186
66
174
138
60

Rated Power (W)
32
22
6.7
17
15
6.5

Noise Level (dBA) *1
47
43
20
38
35
19

CLEAN AIR
&
HUMIDIFY

Humidification (mL / hour) *2
600
480
200
440
370
190

Standby power (W)
1.2

Recommended Room Size (m2) *3
~ 38
~ 28

High density Plasmacluster ion
recommended room size (m2) *4
~ 21
~ 17

Water Tank Capacity (L)
Approx. 2.7

Sensors
Sensitive Dust / Odor / Light / Temperature & Humidity

ENGLISH

Filter Type
HEPA*5 / Deodorizing / Humidifying

Cord Length (m)
2.0

Dimensions (mm)
384 (W) × 230 (D) × 619 (H)

Weight (kg)
Approx. 8.2

*1
• Noise level is measured based on the JEM1467 standard of the Japan Electrical Manufactures' Association.

*2
• The amount of humidification changes in accordance with indoor and outdoor temperature and humidity.
The amount of humidification increases as temperatures rises or humidity decreases.
The amount of humidification decreases as temperatures decrease or humidity rises.
• Measurement Conditions: 20 ºC, 30 % humidity (according to JEM1426).

*3
• The recommended room size is appropriate for operating the product of maximum fan speed.
• The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes
(according to JEM1467).

*4
• Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the
product is placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the
floor.

*5
• The filter removes more than 99.97% of particles at least 0.3 microns in size (according to JEM1467).

Standby Power
When the product’s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical circuits.
To conserve energy, unplug the power cord when the product is not in use.

EN-19