Текст страницы
Unmanaged Rackmountable Switches
Appendix B Specifications
Item
Content
IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x
Standards
IEEE 802.1p (Only for MS116GS/MS124GS)
IEEE 802.3z, IEEE 802.3af, IEEE 802.3at (Except for MS116GS/MS124GS)
10BASE-T: 2-pair UTP/STP of Cat. 3 or above (maximum 100 m)
100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m)
Transmission Medium
1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
1000BASE-LX (Only for MS120GP/MS126CP/MS128GP)
1000BASE-SX/LX10/BX10 (Only for MS118CP/MS120GP/MS126CP/MS128GP)
10Base-T: 14881 pps/Port
100Base-X: 148810 pps/Port
Frame Forward Rate
1000Base-T: 1488095 pps/Port
1000BASE-X: 1488095 pps/Port (Only for MS118CP/MS120GP/MS126CP/MS128GP)
MS116GS: Power, Link/Act, 1000 Mbps
MS124GS: Power, Link/Act
MS118CP: PWR, Link/Act, PoE Status, PoE Max
LEDs
MS120GP: PWR, Link/Act, PoE Status, PoE Max
MS126CP: PWR, Link/Act, PoE Status, PoE Max
MS128GP: PWR, Link/Act, PoE Status, PoE Max
Power Supply
100-240VAC, 50/60Hz
Certification
CE, RoHS
Operating Temperature
MS116GS/MS124GS/MS118CP:
-5 °C to 50 °C (23 °F to 122 °F)
MS120GP:
-10 °C to 50 °C (14 °F to 122 °F)
MS126CP/MS128GP:
-10 °C to 45 °C (14 °F to 113 °F)
Storage Temperature
-40 °C to 70 °C (-40 °F to 158 °F)
Operating Humidity
10% to 90% RH Non-condensing
Storage Humidity
5% to 90% RH Non-condensing
12
Appendix B Specifications