Текст страницы
EN
LASER DISTANCE METER
LASER DISTANCE METER
EN
XP3 GREEN CONDTROL
XP3 GREEN CONDTROL
User manual
User manual
Calculation of distance by 3 additional measurements (Sum of cathetuses)
Bluetooth
Press 4 times
Symbol appears on the display.
Press
Activate Bluetooth function.
Symbol appears on the display. Switch on
Press
First measurement (hypotenuse 1).
Bluetooth in your phone, tablet PC or laptop. For
further operation please use application Smart
Measure CONDTROL.
Press
Second measurement (cathetus).
MESSAGE CODES
Press
Third measurement (hypotenuse 2).
While operation, the following codes/symbols may appear on the display:
Message
Cause
Solution
– hypotenuse 1 (measured)
ERR
Out of measuring range
Use the device within the range.
– cathetus (measured)
– hypotenuse 2 (measured)
ERR 1
Laser signal is too weak
Use the reflecting plate.
– cathetus (calculated)
ERR 2
Laser signal is too strong
Use the reflecting plate.
ERR 3
Low battery voltage.
Сharge or replace the batteries.
Timer
Press
Activate timer. Default value is 5 seconds.
ERR 4
The ambient temperature is
out of the working range.
Use the device in the specified
temperature.
Press or
Adjust the timer response time.
ERR 5
Measuring error in
Pythagoras function.
Measure again and ensure
that hypotenuse is bigger than
cathetus.
Press
Start timer.
ERR 6
Failure of tilt sensor.
Please contact service center.
Memory
Enter memory. A number of saved measuring results is
Press
reflected on symbol on the display.
Press or
Flip through saved measuring results.
17
16