4. Install the laser level closer to the wall B, mark the crossing point
of laser lines as B2 (marks В1 and В2 should be located on the same
vertical line) (see Fig.C).
5. Turn the instrument by 180° and mark the crossing point of the laser
lines on the wall as A2 (marks A1, A2 should be located on the same
vertical line) (see Fig.D).
6. Check the distance dA, dB between marked points A1, A2 and B1, B2
accordingly (see Fig. D). If deviation between dA, dB values exceeds 2
mm, please contact service center.