Error Reporting

The following table shows the values returned in the Status and Error Registers when specific error conditions are
encountered by a device.

Error Condition
Status Register
Error Register

51h
04h

A SMART FUNCTION SET command was received by the device
without the required key being loaded into the Cylinder High and
Cylinder Low registers.

51h
04h

A SMART FUNCTION SET command was received by the device with a
subcommand value in the Features Register that is either invalid or not
supported by this device.

51h
04h

A SMART FUNCTION SET command subcommand other than SMART
ENABLE OPERATIONS was received by the device while the device
was in a “SMART disabled” state.

The device is unable to read its Attribute Values or Attribute Thresholds
data structure.
51h
10h or 40h

The device is unable to write to its Attribute Values data structure.
51h
10h
Table 245 SMART Error Codes

295
Western Digital Ultrastar DC HC310 SATA Product Manual