Текст страницы
12.15.1 Abort NCQ Queue Subcommand (0h)
Table 112 Abort NCQ Queue Subcommand (0h)
Command Input
Field
Description
FEATURE
Bit
Description
15:8
Reserved
7:4
ABORT TYPE field
3:0
Subcommand field – shall be set to 0h
COUNT
Bit
Description
15:14
PRIO field
13:8
Reserved
7:3
NCQ TAG field
2:0
Reserved
LBA
Bit
Description
47:8
Reserved
7:3
TTAG field
2:0
Reserved
DEVICE
Bit Description
7 Reserved
6 Shall be set to one
5 Reserved
4 Shall be cleared to zero
3:0 Reserved
Command
7:0 63h
Normal Outputs
If a supported Abort Type parameter is specified, then the device indicates success, even if the command results in
no commands being aborted.
When an Abort NCQ Queue command completes successfully, a Set Device Bits FIS is sent to the host to complete
the Abort subcommand and commands that were aborted as a consequence of the Abort subcommand by setting
the ACT bits for those commands to one. This SDB FIS may also indicate other completed commands.
Error Outputs
The device returns command aborted if:
a) NCQ is disabled and an Abort NCQ Queue command is issued to the device;
b) the value of the TTAG field equals the value of the TAG field;
c) the value of the TTAG field is an invalid TAG number; or
d) an unsupported Abort type parameter is specified.
178