12.49.6.4 Set Power Condition State subcommand (3h)
Table 210 Set Power Condition State subcommand
Command Block Normal Outputs
Command Block Command Input
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
0
1
0
0
1
0
1
0
Error
…See Below…
Sector Count
V
V
V
V
V
V
V
V
Sector Count
-
-
-
-
-
-
-
-
Sector Number
-
-
V
V
0
0
1
1
Sector Number
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
1
1
0
1
1
1
1
Status
…See Below…
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC UNC 0
IDN 0
ABT T0N AMN
BSY RDY DF
DSC DRQ COR IDX ERR
0
0
0
0
0
V
0
0
0
V
0
-
-
0
-
V
On successful completion of this EPC subcommand, the device updates the Power Conditions log for the Power
Condition as follows:
1) If the Enable bit is set to one, then enable the Current Timer; otherwise disable the Current Timer; and
2) If the Save bit is set to one, then copy the Current Timer Enabled field to the Saved Timer Enabled field.
Output Parameters To The Device
Sector Count
Power Condition ID (See Table 66)
Sector Number bit
Description
7-6
Reserved
5
Enable
1
Enable the selected power condition
0
Disable the selected power condition
4
Save
1
Save settings on completion
0
Do not save settings on completion
3-0
3h Set Power Condition State subcommand (See Table 65)
Error Output
If the Power Condition is not changeable, or not supported, or if Extended Power Conditions feature set is disabling,
then the device returns command aborted. If the Save bit is set to one and the selected power condition is not savable,
then the device returns command aborted. If command aborted is returned, then the device makes no modifications