OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
User manual
User manual
User manual
EXTERNAL APPEARANCE
CongratulaƟ ons on your purchase of opƟ cal level 24X / 32X CONDTROL.
Safety instrucƟ ons provided in this user manual should be carefully read
before you use the product for the fi rst Ɵ me.
2
2
SAFETY REGULATIONS
1
3
14
24X / 32X
AƩ enƟ on! This user manual is an essenƟ al part of this product. The user
manual should be read carefully before you use the product for the fi rst
Ɵ me. If the product is given to someone for temporary use, be sure to
enclose user manual to it.
4
10
1
Optical level
EN
6
7
13
13
9
8
- Do not misuse the product.
- It is prohibited to disassemble or repair the product yourself. Entrust
product repair to qualifi ed personnel and use original spare parts only.
- Store the product beyond reach of children and unauthorized people.
- Do not use the product in explosive environment, close to fl ammable
materials.
9
15
11
12
5
FUNCTIONS/APPLICATIONS
OpƟ cal levels 24X / 32X CONDTROL are professional measuring
instruments. They are equipped with a compensator with a magneƟ c
damping system with working range ± 15‘. It allows to quickly and correctly
make high-precision measurements.
CONDTROL opƟ cal levels have 24X* and 32X** magnifi caƟ on telescope
with coated opƟ cs, which signifi cantly improves visibility and makes aiming
to remote objects easier. They have a horizontal limb with a 1° graduaƟ on
marks and liŌ ing screws, as well as an opƟ cal sight on the telescope for
convenient target search.
*-24Х
**-32Х
- ObjecƟ ve lens
- OpƟ cal peep sight
- Circular vial mirror
- Eyepiece cover
- AdjusƟ ng screw for sighƟ ng line
- Eyepiece
- Circular bubble vial
- Horizontal circle reference mark
- Horizontal circle
- AdjusƟ ng screws of circular bubble vial
- LiŌ ing screws
- Tripod mount 5/8“ (on the rear side)
- Horizontal drive screws
- Focusing screw
- Base
USER MANUAL
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
User manual
User manual
User manual
User manual
TECHNICAL SPECIFICATIONS
24X
32X
Standard deviation for 1 km
double
2 mm
1.5 mm
ACCURACY CHECK AND ADJUSTMENT
Despite the fact that all optical levels with compensator are adjusted
at the factory, it is necessary to carry out accuracy check before use.
1. Checking the circular bubble vial
а) Adjust the lifting screws to center the bubble vial and rotate the
telescope by 180°. The bubble vial should remain in the center (Figure 6).
DELIVERY PACKAGE
1. OpƟ cal level – 1 pc.
2. 2-mm hex wrench - 1 pc.
3. AdjusƟ ng pin - 1 pc.
4. User manual – 1 pc.
5. Hard case – 1 pc.
Image
Direct
Magnification
24x
32x
2. Aiming and focusing
а) Grid:
Point the telescope on a bright surface or leveling staff , using the sight.
Rotate the eyepiece unƟ l you achieve a clear and bright image of the
grid.
в) Aiming:
Rotate the focusing screw forward to focus on the staff
standing at longer distance or back to focus on the staff
standing at closer distance unƟ l a clear image appears on
the screen. Rotate the horizontal drive screw to posiƟ on
the image of the staff at the center of the fi eld of view.
Figure 6
Objective aperture
38mm
OPERATION
1. Instrument set-up and leveling
a) Set desired height of the tripod
and place it on the ground. Use the
aƩ achment screw to Ɵ ghtly fi x the
opƟ cal level on the tripod (Figure 2).
Minimal viewing distance
0.6 m
Stadia Ratio
100
b) If the bubble vial is not in the center, it is necessary to perform
adjustment.
с) Rotate the lifting screws to move the bubble vial halfway to the center
(Figure 7).
Level vial Sensitivity
8’/2 mm
Center
Deviation of the bubble vial
b) Rotate the liŌ ing screws A, B, C to
install the bubble vial in the center.
By rotaƟ ng the A and B screws
simultaneously, move the bubble to the
right. RotaƟ on of the screw C will move
the bubble back (Figure 3).
Horizontal Circle Graduation
1°
Figure 4
Figure 2
Type of compensator
magnetic
Move the bubble vial to position
marked by dashed line
(half of deviation)
Figure 7
7
Range
15’
A
A
B
A
B
Setting Accuracy
0.5”
Protection rate
IP54
3. Measurements
а) Exceedence:
AŌ er poinƟ ng on the staff take the readings of the middle
line, as shown on Figure 4. (the reading is 1.195 m).
в) Distance:
Take the readings of the upper and boƩ om stadia lines.
Distance between the instrument and the staff will be the
following:
(Reading of the upper line – reading of the bott om line) х100,
As shown on the Figure 4:
(1.352 m - 1.038 m) х 100 = 31.4 m
с) Angle:
Point the verƟ cal line of the grid to the
target A and take the angle reading α on the
limb. Point to the target B and take the angle
reading β on the limb. The angle between A
and B will be - α - β (Figure 5).
C
C
Dimensions
210x135x145 mm
B
0
Figure 5
Weight
1.4 kg
d) Turn 2 adjusting screws to
adjust the position of the bubble
vial (Figure 7).
e) Repeat steps from A to D until
the bubble vial doesn’t deviate
from the center (Figure 8).
Figure 3
Thread
5/8”
Figure 8