Otherwise, you perform the following actions:
a) Aim the instrument at the staff B and
remove the eyepiece cover (Figure 11).
2. Check the position of the sighting axis
а) Set leveling staffs А and В at distance 50 m from each other. Set the
instrument right in the middle between the staffs. Level the instrument
and take the readings on the staffs А and B accordingly. Exceedence
between them dh = a1-b1 (Figure 9).
e
e
a1
b
B
Figure 11
h
Using the adjusting pin turn the adjusting screw (Figure 12), until the
reading b3 on the staff B becomes b3=a2-dh.
d
d
A
Figure 9
в) Move the instrument and set it at distance 1-2 m from the staff
A (Figure 10). Level the instrument and take the readings а2 and b2
on the staffs А and В accordingly. If I(a2-b2) - (a1-b1)I < 3 mm, further
adjustment is not needed.
- Store and transport the instrument and its accessories only in the hard
case included in the delivery package.
- Protect the instrument from bumps, falling and intense vibraƟ on, as it can
lead to loss of accuracy.
- Do not expose the instrument to extreme high or low temperatures, as
well as temperature change, as it can lead to loss of accuracy. При больших
перепадах температуры, прежде чем начинать работу с прибором,
сначала дайте ему выровнять свою температуру с температурой
окружающей среды. If there is huge temperature diff erence, allow the
instrument to level its temperature with the ambient temperature fi rst
before start operaƟ on.
- Protect the instrument from moisture, as well as exposure to direct
sunlight.
- There is a bag with a moisture absorber inside the hard case. Replace it
regularly.
- Clean the instrument with a dry and soŌ cloth. Do not use cleaning agents
or solvents.
- Do not touch the lens of the objecƟ ve and eyepiece. Wipe the opƟ cal
surfaces with a soŌ cloth regularly.
- AŌ er working with the instrument, wipe it dry and put it back in the hard
case.
UTILIZATION
Expired tools, accessories and package should be passed for waste recycle.
Please send the product to the following address for proper recycle:
Repeat all of the above steps until the
result satisfies the conditions:
|(a2-b2)-(a1-b1)| ≤ 3 mm.
b1
a2
b
Figure 12
WARRANTY
All CONDTROL GmbH products go through post-producƟ on control and are
governed by the following warranty terms. The buyer‘s right to claim about
defects and general provisions of the current legislaƟ on do not expire.
1) CONDTROL GmbH agrees to eliminate all defects in the product,
discovered while warranty period, that represent the defect in material or
workmanship in full volume and at its own expense.
2) The warranty period is 24 months and starts from the date of purchase by
the end customer (see the original supporƟ ng document).
3) The warranty doesn’t cover defects resulƟ ng from wear and tear or
improper use, malfuncƟ on of the product caused by failure to observe
the instrucƟ ons of this user manual, unƟ mely maintenance and service
and insuffi cient care, the use of non-original accessories and spare parts.
Modifi caƟ ons in design of the product relieve the seller from responsibility
for warranty works. The warranty does not cover cosmeƟ c damage, that
doesn’t hinder normal operaƟ on of the product.
4) CONDTROL GmbH reserves the right to decide on replacement or repair
of the instrument.
5) Other claims not menƟ oned above, are not covered by the warranty.
6) AŌ er holding warranty works by CONDTROL GmbH warranty period is
not renewed or extended.
7) CONDTROL GmbH is not liable for loss of profi t or inconvenience
associated with a defect of the instrument, rental cost of alternaƟ ve
equipment for the period of repair.
This warranty applies to German law except provision of the United NaƟ ons
ConvenƟ on on contracts for the internaƟ onal sale of goods (CISG).
In warranty case please return the product to retail seller or send it with
descripƟ on of defect to the following address:
B
CONDTROL GmbH
Im Wiegenfeld 4
85570 Markt Schwaben
Germany
h
CONDTROL GmbH
Im Wiegenfeld 4
85570 Markt Schwaben
Germany
Figure 10
A
Do not throw the product in municipal waste!
According to European direcƟ ve 2002/96/ЕC expired measuring tools
and their components must be collected separately and submiƩ ed to
environmentally friendly recycle of wastes.
CARE AND MAINTETANCE
AƩ enƟ on! This device is a precision instrument and requires careful
handling. Maintenance of the following recommendaƟ ons will extend the
life of the instrument:
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
OPTICAL LEVEL
CONDTROL 24X/32X
User manual
User manual
User manual
User manual