Текст страницы
GAS STOVE
ADAPTING THE BURNERS TO DIFFERENT TYPES OF GAS
To adapt the appliance to a gas source other than the one it was
configured for, follow these steps:
1. Remove the bars.
2. Remove the caps and flame-spreader crowns. Use a 7 mm spanner to
unscrew and remove the jets.
3. Replace the jets with suitable ones that are supplied with the equipment
(see the table of characteristics of burners and jets).
4. Assemble all components in reverse order.
ATTENTION! If the pressure of the gas used differs from that provided
by the equipment (or is variable), a pressure regulator must be installed on
the inlet pipeline (passable gas) relevant to the standards.
MINIMUM ADJUSTMENT FOR BURNERS
The initial adjustment of the minimum flame level was made at the manufacturer's plant.
After replacing the jet or under special pressure conditions in the network, you will need to
re-adjust the minimum.
The minimum is adjusted in the following order:
1. Light the burner.
2. Turn the control knob to the minimum position.
3. Remove the handle and, if installed, the intermediate
gasket.
4. Use a suitable-sized screwdriver to turn the adjusting
screw located on the side or inside the regulator rod until
the flame is small but steady.
5. Set the handle back and quickly turn it from the maximum position to the minimum, making
sure that the flame does not go out.
6. For burners with a safety valve, make sure that this setting is sufficient to maintain the heating
of the thermocouple. Otherwise, increase the minimum flame level.
MINIMUM ADJUSTMENT FOR LIQUEFIED GAS
To set the minimum for liquefied gas, completely tighten the screw installed inside or on the
side of the valve stem clockwise.
ATTENTION! The burners do not require primary adjustment.
TABLE OF INJECTORS AND GAS FLOW
GAS TYPE
Small burner
Medium burner
Big burner
Oven burner
injector
gas con-
sumption
injector
gas con-
sumption
injector
gas con-
sumption
injector
gas con-
sumption
mbar
(mm)
(g/h)
(mm)
(g/h)
(mm)
(g/h)
(mm)
(g/h)
G30-30
0,55
73
0,70
131
0,85
204
0,65
204
G31-37
0,55
73
0,70
131
0,85
204
0,65
204
LPG
G30-37
0,50
70
0,65
127
0,80
190
0,65
190
G30-50
0,50
76
0,65
145
0,80
207
0,65
207
28