be properly grounded.

5. Insert the noise absorbing screen into the
drain hole flat side up. (Fig.8.3)

Turn ON/OFF device

8. CONNECTING THE OUTLET PIPE

• To the DRAIN PIPE ATTENTION!

Depending on the models BORT disposer are
equipped with two types of control: a wireless
(wall) switch or a pneumatic switch.

• It is recommended to wear protective goggles
when installing the disposer.

Wireless (wall) switch

The disposer of the “Control and FullControl”
series are equipped with a wireless wall mount
switch.

• For all models, the drain pipe is connected us-
ing a screw connection (Fig. 9. 2). First connect
the hydraulic lock to the disposer and then to
the drain. For the connection a siphon with
smooth walls should be used.

The switch should be located in a convenient
(safe for children) place above the table top.

• Use a sanitary sealant only for connecting the
flange of the sink with the disposer.

For instal the switch to the wall, use double–
sided tape.

For activate / deactivate the device, hold down
the key for 2–3 seconds.

• Do not use sealants for threaded pipe connec-
tions or anaerobic screwed sealants. They can
damage the product.

Battery type: Voltage: 12V; Size: A27

Air switch

• Regularly check the disposer and fittings for
water leaks, since leaks water can cause dam-
age to property.

Disposer is equipped with an air switch and a
connecting pipe (except “Control” series).

INSTALLATION OF AIR SWITCH

• The manufacturer is not responsible for dam-
age to property as a result of water leaks.

INSTALLING THE DRAINAGE SYSTEM

1. Drill a hole with a diameter of 32 mm in suit-
able top or top the panel of a sink. Some sinks
may already have a suitable A hole for the open-
ing of which is necessary remove the cover.

1. Put the flange (2) on the drain pipe Insert the
rubber seal (1). Fasten drain tube, tightly pulling
it to the body disposer with screws (4). (Fig. 9. 1)

9. CONNECTING THE DISPOSER TO THE ELEC-
TRICAL NETWORK

ATTENTION! ELECTRIC SHOCK CURRENT

2. Unscrew the nut from the body of the push
button, while holding the stainless steel washer
and rubber gasket in place. Place one end of the
PVC tube on the spout on the body Press the
other end to A hole in the table top and a nut lo-
cated under the countertop. (Fig. 10. 2)

To prevent electric shock, turn off the power be-
fore installing or servicing the product.

If you are not qualified enough, call an electrician
to connect the product to the power.

3. Place the push button housing in the hole and
tighten the nut underneath countertop (enough
arm effort). Do not use the key to tighten nut.
(Fig. 10. 3)

If a three–pin grounding–type plug is used to
connect a three–contact outlet with ground.

Do not modify the design of the plug supplied
with the device.

Improper equipment grounding may cause elec-
tric shock current.

All electrical connections must comply with the
electrical and norms.

Do not connect the ground to the feed pipe gas.

4. Take the other end of the duct and tightly put
it on the spout of the air switch located on the
bottom of the disposer. (Fig. 10. 4) Hand tighten
the clamping nut. The disposer installation is
complete. Before using the product, read all of
the instructions. operation and safety contained
in paragraph 10 of this manual. In conclusion, in-
stall the plug in the sink in the Closed position.
Fill the sink with water, Remove the plug and
check the connections on the a water leakage.

Do not power on the distribution shield until you
have installed the sockets with proper ground-
ing.

10. ATTENTION! IMPORTANT INSTRUCTIONS
FOR

SAFETY

If the power cord is damaged, it must be re-
placed at the service center.

• If the air switch does not work, remove the plug
power supply from the outlet and check the air
duct pneumatic switch and delivered to the

NOTE: Access to a grounded outlet is required.
Installing all additional outlets must be carried
out by a qualified electrician, and all outlets must

12