Текст страницы
Disassembly and Assembly
Reassembly
Leaving screws inside the device may damage internal components, such as the
battery. When assembling, be extra careful not to leave any unassembled screws
inside the device.
1 Apply the adhesive (FULLER EH9377) on the upper and lower side to attach the new hinge.
As it could be harm for the body, use the adhesive carefully.
• If you have already used this adhesive for other assembly or if the adhesive on
the needle part is hardened, you can replace only the needle with a new one
and continue to use it.