Текст страницы
Operation
■ HOW TO USE
1. Pour the solution into the tank with the
WARNING
• Before the solution spraying work, supply
intermediate valve closed.
water into the tank and operate the mister to
make sure that there is any leakage or any
mechanical failure.
• Repair it if there is any leakage or failure
before the solution spraying work.
Discharge rate
Valve travel
(lit/min.)
1
1
2
2
3
3
4
4
2. Adjust the solution flow and the spray range
according to work conditions.
Max. Longitudinal coverage
Horizontal direction :
12 m
Vertical direction :
12 m
The solution flow is changed by shifting the
number on the top of the valve at the mist
nozzle. The figure shows 4 lit/min. position.
The spray range is changed by shifting the bell
position after loosening the lock ring.
(A) Pulled out position: Long distance, narrow angle
spray
(B) Pushed In position: Short distance, wide angle
spray
- Start the engine and carry the unit on your back.
- While holding the swivel joint in your right hand,
move the throttle lever upward and turn the
intermediate valve to the open position.
5. After spraying work has finished, close the
intermediate valve and stop the engine.
English - 11