Текст страницы
Product Specification Model No.: GP210AAHC Document Number: MQS3553 Revision: 03 Page 3 of 5
3. PERFORMANCE
Unless otherwise stated, tests should be done within one month of delivery under the following conditions :
Ambient Temperature, Ta : 20 + 2oC and
Relative Humidity : 65 + 20%.
Notes : Standard Charge / Discharge Conditions:
Charge : 200mA (0.1C) x 16hrs
Discharge : 400mA (0.2C) to 1.0V/cell
Test
Unit
Specification
Conditions
Remarks
Capacity
mAh
≧2000
Standard Charge/Discharge
Up to 3 cycles are
allowed
Open Circuit
Voltage(OCV)
V
≧ 1.25
Within 1hr after standard
charge
Internal Impedance
(Ri)
mΩ
≦ 28
Upon fully charge
At 1kHz
High Rate
Discharge (0.5C)
min
≧ 108
Standard charge, 1hr rest
before discharge
High Rate
Discharge (1C)
min
≧51
Standard charge, 1hr rest
before discharge
Overcharge
N/A
No conspicuous
deformation and /
or leakage
200mA (0.1C) charge 1 year
Charge Retention
mAh
≧1600
Standard Charge
Storage: 12 months at 20 oC
Standard Discharge
IEC Cycles Test
Cycle
> 500
IEC61951-2(2011) 7.5.1.2
(see Note 3)
Leakage
N/A
No leakage
Fully charged at 2000mA(1C),
stand for 14 days
Manufacturer reserves the right to alter or amend the design, model and specification without prior notice.