Текст страницы
www.seagate.com
SATA Interface
4.3.1
Identify Device command
The Identify Device command (command code ECH) transfers information about the drive to the host following power up.
The data is organized as a single 512-byte block of data, whose contents are shown in Table 6 on page 23. All reserved
bits or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive.
The following commands contain drive-specific features that may not be included in the SATA specification.
Table 7
Identify Device commands
Word
Description
Value
0
0C5AH
Configuration information:
• Bit 15: 0 = ATA; 1 = ATAPI
• Bit 7: removable media
• Bit 6: removable controller
• Bit 0: reserved
1
Number of logical cylinders
16,383
Specific configuration:
2
C837H
37C8h Device requires SET FEATURES subcommand to spin-up after power-up
and IDENTIFY DEVICE data is incomplete.
738Ch Device requires SET FEATURES subcommand to spin-up after power-up
and IDENTIFY DEVICE data is complete.
8C73h Device does not require SET FEATURES subcommand to spin-up after
power-up and IDENTIFY DEVICE data is incomplete.
C837h Device does not require SET FEATURES subcommand to spin-up after
power-up and IDENTIFY DEVICE data is complete.
3
Number of logical heads
16
4
Retired
0000H
5
Retired
0000H
6
Number of logical sectors per logical track: 63
003FH
7–9
Retired
0000H
10–19
Serial number: (20 ASCII characters, 0000H = none)
ASCII
20
Retired
0000H
21
Retired
0400H
22
Obsolete
0000H
23–26
Firmware revision (8 ASCII character string, padded with blanks to end of string)
x.xx
27–46
Drive model number: (40 ASCII characters, padded with blanks to end of string)
47
(Bits 7–0) Maximum sectors per interrupt on Read multiple and Write multiple (16)
8010H
Trusted Computing feature set options:
48
4000H
15
Shall be cleared to zero
14
Shall be set to one
13:1 Reserved for the Trusted Computing Group
0
Trusted Computing feature set is supported
49
Standard Standby timer, IORDY supported and may be disabled
2F00H
Capabilities: (see 7.17.7.17)
50
4000H
15 Shall be cleared to zero
14 Shall be set to one
13:2 Reserved
1 Obsolete
0 Shall be set to one to indicate a vendor specific Standby timer value minimum
Seagate SkyHawk Product Manual, Rev. A