Текст страницы
1. Selection of the welding method:
1) In the main interface, press the MENU key to enter the function selection interface;
2) In the function selection interface, rotate L Knob to select the TIG Lift welding method and
press it for confirmation. Refer to Fig. 1;
2. Selection and setting of welding parameters:
1) In the main interface, press the MENU key to enter the welding parameter setting interface;
2) In the welding parameter setting interface, rotate L Knob to select the parameter as required
and rotate R Knob to set a value for the parameter, afterwards, press L Knob or R Knob for
confirmation as shown below:
Welding parameters
available by rotating
R Knob
Welding parameters
available by rotating L
Knob
Two/four Stroke
2T/4T
Pre-flow
0-2 S
Down Slope
0-10 S
Post Flow
0-10 S
3. Setting of welding current:
1) Press the ENTER key to enter the welding interface as shown below:
2) In the welding interface, rotate L Knob to set the welding current (10 - 200 A), and then press it
for confirmation;
Note:1. In the welding process, press the MENU key to return to the main interface and
re-set parameters, and then press the ENTER key to enter the welding interface;
2. In the function selection interface, rotate L Knob to select a welding method as
required and press L Knob two times to directly enter the welding interface.
15