8.3 Cleaning the Control Panel
EN
RU
KK
1
Burner cap
2
Burner head
3
Burner chamber
4
Spark plug (in models with ignition)
• When cleaning the panels with knob-con-
trol, wipe the panel and knobs with a
damp soft cloth and dry with a dry cloth.
Do not remove the knobs and gaskets un-
derneath to clean the panel. The control
panel and knobs may be damaged.
• While cleaning the inox panels with knob
control, do not use inox cleaning agents
around the knob. The indicators around
the knob can be erased.
• Clean the touch control panels with a
damp soft cloth and dry with a dry cloth.
If your product has a key lock feature, set
the key lock before performing control
panel cleaning. Otherwise, incorrect de-
tection may occur on the keys.
9
Troubleshooting
If the problem persists after following the
instructions in this section, contact your
vendor or an Authorized Service. Never try
to repair your product yourself.
There is no gas.
• Main gas valve is closed. >>> Open the
gas valve.
• The gas pipe is bent. >>> Install the gas
pipe properly.
The product does not work.
• Fuse may be faulty or blown. >>> Check
the fuses in the fuse box. Change them if
necessary or reactivate them.
• The appliance may not be plugged to the
(grounded) outlet. >>> Check if the appli-
ance is plugged in to the outlet.
• (If there is timer on your appliance) Keys
on the control panel do not work. >>> If
your product has a key lock, the key lock
may be enabled, disable the key lock.
Burners are not burning properly or at all.
• The burners are dirty. >>> Clean the
burner parts.
• Burners are wet. >>> Dry the burner parts.
• Burner cap is not mounted safely. >>>
Place the burner cap properly.
• Gas valve is closed. >>> Open the gas
valve.
• Gas cylinder is empty (when using LPG).
>>> Replace the gas cylinder.
There is no ignition spark.
• There is no current. >>> Check the fuses
in the fuse box.
EN / 30