Текст страницы
M3X8 Screw
Fuser
Tip:
Please first loosen the pressure spring before removing the fixing screws.
The green arms as shown need to be pulled up while disassembling the pressure spring. Or the pressure
spring will be deformed.
The sprint hook used to release the pressure spring, see below.
2.5.2
Control Panel
Tool Preparation: No. 3(Refer to Maintenance Tool List)
(1) Remove Front Cover, Paper Tray, Drum Unit, and the Right Cover.
(2) Remove M3X6 fixing screws x 2, and also remove the FFC cable.
Note :
• After unplugging the flat cable, be sure to check that the connectors of the flat cable are intact and
that the flat cable is not short-circuited。
• When inserting the flat cable, be sure to insert it straight and make sure that it is not crooked.
47
Confidential