Текст страницы
2.5.15 Fuser Out Sensor Lever
Tool Preparation: No. 1、3 (Refer to Maintenance Tool List)
(1). Remove Front Cover, Paper Tray, Drum Unit, Duplex unit, Right Cover, and Rear Cover.
(2). Remove Fuser Out Path and then open the lever with a flat screw driver (small) to remove the lever.
Fuser out path
Lever
2.5.16 Paper-in Sensor (Manual Tray)
Tool Preparation: No. 1、3 (Refer to Maintenance Tool List)
(1). Remove Front Cover, Paper Tray, Drum Unit, Duplex unit, and Paper-in Sensor.
(2). Remove 2 fixing screws TS3x8 and then disconnect the manual tray paper-in sensor cable to remove
the manual path.
(3). Turn over the manual tray and open the latch with a small flat screw driver to remove the manual tray
paper-in sensor.
Manual path
TS3X8 Screw
58