Текст страницы
Main Board
TS3X8 Screw
TS3X10 Screw
Note :
• After unplugging the flat cable, be sure to check that the connectors of the flat cable are intact
and that the flat cable is not short-circuited.
• When inserting the flat cable, be sure to insert it straight and make sure that it is not crooked.
2.5.6
Power Supply Board
Tool Preparation: No. 3(Refer to Maintenance Tool List)
(1). Remove Front Cover, Paper Tray, Drum Unit, and the Right Cover.
(2). Remove all cables (3pcs) connecting to the Power Supply Board.
(3). Remove TS3X8 screws x 6 pcs, and TS3X10 ground screw x 1 to remove the Power Supply Board.
Note :
• After the high-voltage board is removed, some components will still be conductive. Please wear
latex gloves to work. Do not touch the welding surface of the high-voltage board without gloves.
• After the high-voltage board is disassembled, it should be placed on a insulating surface to avoid
damage to the high-voltage board due to power jump.
High Voltage
Signal (9P)
Low Voltage to
DC 24V(10P)
To Fuser (2P)
51
Confidential