5. Slide a suitable receptacle under
16.3 Cleaning the drain pump
the opening for draining the deter-
gent solution.
Clean the drain pump regularly, at
least once a year, as well as in the
event of faults, e.g. blockages or rat-
tling noises.
Note
Scan the QR code to see an anima-
tion of the process.
Observe the following safety instruc-
tions before you start the animation.
6. Take the drain hose out of the
holder.
Emptying the drain pump
- Turn off the tap.
- Switch off the appliance.
→ Page 30
3. Disconnect the appliance's mains
plug from the power supply.
4. Open and remove the mainten-
ance flap.
33