Текст страницы
Fuser Error(201600)
The temperature of the heating lamp exceeds max. degrees (210 degrees).
< User Check >
(1) Turn off and on the printer.
(2) Turn off the power.
Step
Cause
Solution
1
Thermistor malfunctioned.
Replace the fuser.
2
Main board malfunctioned.
Replace the main board..
Fuser Error(201604)
ADC Calibration Not Ready
< User Check >
(1) Turn off and on the printer.
(2) Turn off the power.
Step
Cause
Solution
1
Main board malfunctioned.
Replace the main board..
Fuser Error(201605)
ADC Not Ready:The ADC-value query for Side and Center Lamp failed every 100ms.
< User Check >
(1) Turn off and on the printer.
(2) Turn off the power.
Step
Cause
Solution
1
Main board malfunctioned.
Replace the main board..
Fuser Error (201607)
Temperature difference between the center and the two sides of the lamp over 40 degrees.
< User Check >
(1) Turn off power and then turn on.
(2) Turn off the power.
Step
Cause
Solution
1
Operating temperature too low.
Change the operating temperature and
restart the printer.
2
Used voltage too low
Check power and avoid using
overloaded electrical appliances on the
same line.
Fuser Error(201613)
The temperature of the Center lamp is more than 20 degrees different from the last time.
< User Check >
(1) Turn off and then on the power.
(2) Turn off the power.
Step
Cause
Solution
1
main board malfunctioned
Replace the main board.组件
Fuser Error(201615)
The thermistor in the middle of the Fuser did not rise to the specified temperature within the specified time:
From normal temperature to Ready state, the center thermistor did not heat up from -20 degrees to 0
degrees within 5.5 seconds.
< User Check >
Confidential